background image

SuperiorFireplaces.us.com

126628-01_J

14

Figure 23 - Glass Doors

Figure 24 - Damper Handle Location

Cleaning Glass

Clean glass with any commercial glass cleaner or soap and water. Do 

not use any abrasive material to clean the glass. Do not clean glass 

with any cool water if glass is still hot from fire and smoke.

DAMPER HANDLE OPERATION

Damper handle, which opens and closes damper blade, is located 

inside firebox at center towards back wall (see Figure 24). Pushing 

handle back into keyway slot will free damper blade to automatically 

open. To close, push handle back into keyhole slot then pull down 

and forward to lock it in place (see Figure 25). Vent damper must be 

locked in the full open position before operating fireplace.

 WARNING: Risk of fire! Replace grate with IHP 

model 107001-01 only. This grate has been designed to 

keep the operation of your fireplace safe and efficient.

OPERATION AND MAINTENANCE

Doors Fully Closed

Doors Fully Opened

Figure 25 - Damper Rod

Fireplace Front

Fireplace Front

Damper 

Handle

1

2

3

1

2

3

Damper 

Weight

To Close Damper

To Open Damper

GLASS DOORS

Glass doors are optional with this fireplace. When fireplace is in 

operation, doors must be fully opened or fully closed position only 

or a fire hazard may be created (see Figure 23).
A fireplace equipped with glass doors operates much differently than 

a fireplace with an open front. A fireplace with glass doors has a 

limited amount of air for combustion. Excessive heat within fireplace 

can result if too large a fire is built or if combustion air gate is not 

completely open.
The following tips should be used to assure that both fireplace and 

glass door retain their beauty and function properly. Both the flue 

damper and glass doors must be fully opened before starting a 

fire. This will provide sufficient combustion air and maintain safe 

temperatures in firebox.

IMPORTANT: 

The glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

F, which is more than a normal fire will generate. Such materials as 

pitch/wax laden logs, very dry mill end lumber and large amounts 

of paper or cardboard boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always keep fire back from 

doors and never allow flames to contact glass.

   WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE.

 WARNING: Discontinue use of the appliance 

immediately if doors are damaged and contact a 

qualified installer for repair. Only doors certified 

with the appliance shall be used.

 WARNING: Do not slam or strike doors. Damage 

can result in a hazardous condition.

Содержание WCT2036WS

Страница 1: ...The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autor...

Страница 2: ...tested for the fireplace system you may cause a fire hazard The IHP warranty will be voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace componen...

Страница 3: ...oseasignificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT...

Страница 4: ...T LESS THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT 13 7 8 353 mm 9 1 8 232 mm 3 4 19 mm...

Страница 5: ...iling flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extensi...

Страница 6: ...l Safe Zone For Projection of Combustible Materials Upper Section of Circulating Fireplace Top of Louvered Opening Fireplace Opening Note Drawing Not to Scale 8 204 mm 1 26 mm Min 12 305 mm from Perpe...

Страница 7: ...eceptacle and Ground Sheet Metal Screws Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of x 20 7 mm x 508 mm in size Air Inlet Location Must Allow For Bushes or Snow V...

Страница 8: ...cal chimney pipe supported ONLY by the fireplace must not exceed 20 feet Chimney heights above 20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combina...

Страница 9: ...Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m A B C Ceiling Support Pipe 12S 8DM Ceiling Support Pipe 12S 8DM Figure 10 Cei...

Страница 10: ...A Screws OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 25 3 4 1 11 7 8 31 1 15 37 3 8 1 16 3 4 40 1 2 1 1 20 47 1 8 1 22 5 8 52 1 8 1 1 25 1 2 57 7 8 1 27 5 8 62 1 1 30...

Страница 11: ...l it is snug against open edge of flashing see Figure 16 Use SC1 for all round termina tions Apply waterproof caulk around perimeter of collar to provide a proper seal Figure 16 Storm Collar Chimney P...

Страница 12: ...shroud is to be installed contact manufacturer for specifications 24 610 mm Min 24 610 mm Min 18 458 mm Min Typ Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0...

Страница 13: ...ment Install gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap...

Страница 14: ...h glass doors operates much differently than a fireplace with an open front A fireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too la...

Страница 15: ...used if installed in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the...

Страница 16: ...16 PARTS WOOD BURNING FIREPLACE MODELS WRT2036WS WRT2036WSI WCT2036WS WCT2036WSI MODEL CAT NO WRT2036WS F0683 WRT2036WSI F0684 WCT2036WS F0685 WCT2036WSI F0686 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18...

Страница 17: ...ner 1 13 See Page 18 Right Side Brick Liner 1 14 See Page 18 Bottom Brick Liner 1 15 See Page 18 Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulat...

Страница 18: ...to obtain any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 ACCESSORIES REFRACTORY STAIN K...

Страница 19: ...Snap Lock F0882 18 8HT 18 Section Hi Temp Double Wall Pipe Snap Lock F0883 24 8HT 24 Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT...

Страница 20: ...UVERS AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE T...

Страница 21: ...nditions inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the app...

Страница 22: ...ance The best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...6628 01 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult yo...

Отзывы: