background image

Superiorfireplaces.US.com

900671-00_NC

19

ACCESSORIES 

Continued

ROUND TOP TERMINATIONS WITH LOUVERS

F0918

RLT-8DM

Round Top with Louvered Screen

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

ROUND TOP TERMINATIONS WITH LOUVERS W/SLIP SECTION

F0919

RLTT-8DM

Round Top with Slip Section & Louvers

F0891

RLTT-8HT

Hi-Temp Round Top w/Lvrd. Screen and Slip Section

SQUARE TOP TERMINATION WITH LOUVERS

F0920

ET-8DM

Square Top

F0892

ET-8HT

Hi-Temp Pyramid Top with Slip Section

SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION

F0921

ETL-8DM

Square Top with Slip Section

F0893

ETL-8HT

Hi-Temp Large Pyramid Top with Slip Section

MESH SQUARE TOP TERMINATION

F0922

ETO-8DM

Square Top with Mesh

MESH SQUARE TOP TERMINATION WITH SLIP SECTION

F0923

ETLO-8DM

Square Top with Mesh and Slip Section

ADJUSTABLE HOOD

Required when installing a vent-free gas log in this fireplace.

F1764

GA6050

Black Fireplace Hood

ADJUSTABLE FIRESTOP THIMBLE

Not shown

F2696

LB-97008A

Adjustable Firestop Thimble

LABEL-UL127-50PK

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

 WARNING

 

   HOT

• 

Fire Risk

• 

Insulation and combustibles must not touch 

pipe

• 

Consult manual for clearance requirements

• 

Ensure proper connection

900599-01

F2659

LABEL-UL127-

50PK

UL127 Venting Label - 50 PK

FAN KIT (INCLUDED)

F1083

BK3

3-Blade Fan  Kit

VENT KIT*

DESCRIPTION

J1948

MW8K

(8' Vent Kit)

J1952

MW9K

(9' Vent Kit)

F2122

MW8K-HT

(8' HT Vent Kit)

36-8DM

36" Double Wall Pipe

2

2

0

24-8DM

24" Double Wall Pipe

1

0

0

18-8DM

18" Double Wall Pipe

0

2

0

LB97008A

Adjustable Firestop Thimble

1

1

1

V6F-8DM

Roof Flashing

1

1

1

SC1-1

Storm Collar

1

1

1

RTL-8DM

Round Cap Termination

1

1

0

RLT-8HT

Round Louvered Termination

0

0

1

36-8HT

36" Flue, 8" HT.

0

0

2

24-8HT

24" Flue, 8" HT.

0

0

1

*Use for Most Common Manufactured (Mobile) Home Installations

Содержание MHWB36CB

Страница 1: ...ent free log heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determ...

Страница 2: ...n sibility for the following actions a Modificationofthefireplace components doors airinletsystem and damper control b Use of any component part not manufactured or approved by IHP in combination with...

Страница 3: ...efluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service technician Some people are more affected by carbon monoxide than...

Страница 4: ...S THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT LEFT SIDE 13 7 8 353 mm 9 1 8 232 mm 3 4 1...

Страница 5: ...stem is 50 feet This measurement includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 27 page 13 FRAMING 1 Frame opening for fireplace using di...

Страница 6: ...o Combustible Material 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 6 153 mm Min 9 229 mm Min 12 305 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of Combustible Materials Uppe...

Страница 7: ...ach outside air vent termination 6 Construct an 8 x 8 inside framing or opening on exterior wall 7 Install outside air vent termination in a location that would not eventually be obstructed by bushes...

Страница 8: ...Install the thimble from below a finished roof and ceiling assembly Push the thimble assembly tube section first up into an already prepared opening and secure open end of the thimble base to the fini...

Страница 9: ...boveceilinglevel firestopspacermustbeinstalled on the bottom side of the ceiling If an attic is above ceiling level firestop thimble must be installed on the bottom side of ceiling joist Figure 14 Not...

Страница 10: ...64 1 2 134 3 8 1 2 1 67 1 4 139 5 8 4 VENTING INSTALLATION Continued Figure 14 Installing Thimble Outer Pipe Thimble Cathedral Ceiling 14 Min Outer Pipe Of Chimney PENETRATING ROOF To maintain a 1 cle...

Страница 11: ...etrate inner stainless FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance be...

Страница 12: ...3 Places Secure with Screws RLT 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 23 Termination Overlap Shingles Top and Sides Flue Pipe of RLT 8DM Inside Inner...

Страница 13: ...92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 25 10 Foot Rule CHIMNEY SUPPORT BRACKET KIT CSK 8DM If exposed portion of chimney is greater than five feet above roofline support wires are recom...

Страница 14: ...g that the gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERAT...

Страница 15: ...in this fireplace Always keep fire back from doors and never allow flames to contact glass OPTIONAL GAS LINE INSTALLATION Continued FINISHING FIREPLACE Combustible materials such as wallboard gypsum...

Страница 16: ...yhole slot then pull down and forward to lock it in place see Figure 34 Vent damper must be locked in the full open position before operating fireplace Figure 33 Damper Handle Location Damper Handle W...

Страница 17: ...fireplace ready You can also visit our web site at Superiorfireplaces US com CAT NO MODEL DESCRIPTION BI FOLD GLASS DOORS F0972 BDB36 36 Standard Black Finish Included F0973 BDB36B 36 Standard Brushed...

Страница 18: ...600FS 8DM 1 1 Clearance Firestop Spacer ROOF FLASHING F0909 V6F 8DM Roof Flashing 0 to 6 12 Pitch 30 Base F0910 V12F 8DM Roof Flashing 6 12 to12 12 Pitch CHIMNEY SUPPORT BRACKET KIT Support Bracket Se...

Страница 19: ...ce Hood ADJUSTABLE FIRESTOP THIMBLE Not shown F2696 LB 97008A Adjustable Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clea...

Страница 20: ...Superiorfireplaces US com 900671 00_NC 20 PARTS WOOD BURNING FIREPLACE MODEL MHWB36CB 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 30 13 29 8 26 6 19 21...

Страница 21: ...Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20 J6918 Top Standoff 4 21 J6893 Chimney Starter Collar 1 22 Door...

Страница 22: ...4 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Suppor...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...aler name P900671 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produc...

Отзывы: