Figure 35 - Locating Access Cover Plate
Access
Cover Plate
Fan
Compartment
Figure 34 - Damper Rod
1
2
3
1
2
3
Damper
Weight
To Close Damper
To Open Damper
OPERATION AND MAINTENANCE GUIDELINES
Continued
Figure 32 - Adjusting Bi-Fold Doors
Cleaning Glass
Clean the glass with any commercial glass cleaner or soap and water.
Do not use any abrasive material to clean glass. Do not clean glass
with any cool water if glass is still hot from fire and smoke.
DAMPER HANDLE OPERATION
Damper handle, which opens and closes damper blade, is located
inside firebox at center towards back wall (see Figure 33). Pushing
handle back into keyway slot will free damper blade to automatically
open. To close, push handle back into keyhole slot then pull down
and forward to lock it in place (see Figure 34). Vent damper must be
locked in the full open position before operating fireplace.
Figure 33 - Damper Handle Location
Damper
Handle
WARNING
Risk of fire! Replace grate with IHP part no. 107001-01
(J4001) only. This grate has been designed to keep
the operation of your fireplace safe and efficient.
LOCATING ACCESS COVER PLATE/FAN COMPARTMENT
Sheet metal access cover plate located underneath front hearth refractory
may have shifted or moved out of place while fireplace was in transit. This
access cover plate must be kept in the proper location prior to using the
fireplace (See Figure 35).
Door Adjustment
Remove doors and slightly loosen lower pivot clips and upper spring
clips. Replace doors and fully close them. Use 1/8" shims (any mate
-
rial) to level doors. Once proper setting is achieved, carefully open
doors enough so that you can access spring clips with a phillips
screwdriver. Tighten screws. See Figure 32.