Figure 30 - Glass Doors

Door Removal

1.  Fold doors (fully open) and press up on upper door spring clip 

until top pin is free of the spring clip (see Figure 31). Tip door 

toward middle of fireplace opening and lift door out of the lower 

pivot hole.

2.  Repeat step 1 for remaining door.

OPERATION AND MAINTENANCE GUIDELINES

Doors Fully Closed

Doors Fully Opened

Fireplace Front

Fireplace Front

GLASS DOORS

Glass doors are standard with fireplace. When fireplace is in opera-

tion, doors must be FULLY OPENED or FULLY CLOSED position only 

or a fire hazard may be created (see Figure 30).
A fireplace equipped with glass doors operates much differently 

than a fireplace with an open front. A fireplace with glass doors 

has a limited amount of air for combustion. Excessive heat within 

fireplace can result if too large a fire is built or if combustion air gate 

is not completely open. The following tips should be used to assure 

that both fireplace and glass door retain their beauty and function 

properly. Both the flue damper and glass doors must be fully opened 

before starting a fire. This will provide sufficient combustion air and 

maintain safe temperatures in firebox.

IMPORTANT: 

Glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

Fahrenheit, which is more than a normal fire will generate.
Such materials as pitch/wax laden logs, very dry mill end lumber, and 

large amounts of paper or cardboard boxes can create an excessively 

hot fire and should not be burned in this fireplace. Always keep fire 

back from doors and never allow flames to contact glass.

OPTIONAL GAS LINE INSTALLATION  

Continued

FINISHING FIREPLACE

Combustible materials, such as wallboard, gypsum board, sheet rock, drywall, plywood, etc. may make direct contact with sides and top around 

the fireplace face. It is important that combustible materials do not overlap the face itself. Brick, glass, tile or other noncombustible materials 

may overlap the front face provided they do not obstruct essential openings like louvered slots or any other opening. When overlapping with a 

noncombustible facing material, use only noncombustible mortar or adhesive.

     WARNING

Fireplaces equipped with glass doors should be 

operated only with doors fully opened or fully closed. 

Doors, if left partly open, may draw gas and flame 

out of the fireplace opening creating risks of both 

fire and smoke.

     WARNING

Discontinue use of the appliance immediately if 

doors are damaged and contact a qualified installer 

for repair. Only doors certified with the appliance 

shall be used.

     WARNING

Do not slam or strike doors. Damage can result in 

a hazardous condition.

Figure 31 - Removing / Installing Bi-Fold Doors

Spring 

Clip

Insert Pin into 

Spring Clip

Pivot Hole

Insert Bottom 

Pivot Pin into Hole

Fold Door and 

Slide Top Pins 

Into Track

Installing Glass Door

1.  With bi-fold doors completely folded, insert bottom pivot pin 

into pivot hole located near bottom corner of front face opening 

and swing door to vertical position making sure top pins slide 

into door track. Door is installed when top door pin snaps into 

spring clip (see Figure 31).

2.  Repeat step 1 for remaining door.
If you find the doors do not close properly or do not appear level or 

straight, proceed with section on door adjustment.

Содержание MHWB36CB

Страница 1: ...ent free log heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determ...

Страница 2: ...n sibility for the following actions a Modificationofthefireplace components doors airinletsystem and damper control b Use of any component part not manufactured or approved by IHP in combination with...

Страница 3: ...efluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service technician Some people are more affected by carbon monoxide than...

Страница 4: ...S THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT LEFT SIDE 13 7 8 353 mm 9 1 8 232 mm 3 4 1...

Страница 5: ...stem is 50 feet This measurement includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 27 page 13 FRAMING 1 Frame opening for fireplace using di...

Страница 6: ...o Combustible Material 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 6 153 mm Min 9 229 mm Min 12 305 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of Combustible Materials Uppe...

Страница 7: ...ach outside air vent termination 6 Construct an 8 x 8 inside framing or opening on exterior wall 7 Install outside air vent termination in a location that would not eventually be obstructed by bushes...

Страница 8: ...Install the thimble from below a finished roof and ceiling assembly Push the thimble assembly tube section first up into an already prepared opening and secure open end of the thimble base to the fini...

Страница 9: ...boveceilinglevel firestopspacermustbeinstalled on the bottom side of the ceiling If an attic is above ceiling level firestop thimble must be installed on the bottom side of ceiling joist Figure 14 Not...

Страница 10: ...64 1 2 134 3 8 1 2 1 67 1 4 139 5 8 4 VENTING INSTALLATION Continued Figure 14 Installing Thimble Outer Pipe Thimble Cathedral Ceiling 14 Min Outer Pipe Of Chimney PENETRATING ROOF To maintain a 1 cle...

Страница 11: ...etrate inner stainless FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance be...

Страница 12: ...3 Places Secure with Screws RLT 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 23 Termination Overlap Shingles Top and Sides Flue Pipe of RLT 8DM Inside Inner...

Страница 13: ...92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 25 10 Foot Rule CHIMNEY SUPPORT BRACKET KIT CSK 8DM If exposed portion of chimney is greater than five feet above roofline support wires are recom...

Страница 14: ...g that the gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERAT...

Страница 15: ...in this fireplace Always keep fire back from doors and never allow flames to contact glass OPTIONAL GAS LINE INSTALLATION Continued FINISHING FIREPLACE Combustible materials such as wallboard gypsum...

Страница 16: ...yhole slot then pull down and forward to lock it in place see Figure 34 Vent damper must be locked in the full open position before operating fireplace Figure 33 Damper Handle Location Damper Handle W...

Страница 17: ...fireplace ready You can also visit our web site at Superiorfireplaces US com CAT NO MODEL DESCRIPTION BI FOLD GLASS DOORS F0972 BDB36 36 Standard Black Finish Included F0973 BDB36B 36 Standard Brushed...

Страница 18: ...600FS 8DM 1 1 Clearance Firestop Spacer ROOF FLASHING F0909 V6F 8DM Roof Flashing 0 to 6 12 Pitch 30 Base F0910 V12F 8DM Roof Flashing 6 12 to12 12 Pitch CHIMNEY SUPPORT BRACKET KIT Support Bracket Se...

Страница 19: ...ce Hood ADJUSTABLE FIRESTOP THIMBLE Not shown F2696 LB 97008A Adjustable Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clea...

Страница 20: ...Superiorfireplaces US com 900671 00_NC 20 PARTS WOOD BURNING FIREPLACE MODEL MHWB36CB 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 30 13 29 8 26 6 19 21...

Страница 21: ...Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20 J6918 Top Standoff 4 21 J6893 Chimney Starter Collar 1 22 Door...

Страница 22: ...4 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Suppor...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...aler name P900671 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produc...

Отзывы: