background image

Superiorfireplaces.US.com

900671-00_NC

2

Safety .............................................................................................2

Specifications .................................................................................4

Fireplace Installation ......................................................................5

Venting Installation ........................................................................7

Optional Gas Line Installation ......................................................14

Operation and Maintenance Guidelines ........................................15

Replacement Parts .......................................................................17

Technical Service .........................................................................17

Accessories ..................................................................................17

Parts ............................................................................................20

Warranty ......................................................................................23

Thank you for your purchase. We appreciate your 

business!

Please carefully read and follow all instructions in this manual. 

Pay 

special attention to all warnings and safety information.

Following these safety, care, and operation instructions will help 

ensure many years of dependable and enjoyable service from your 

fireplace.

Please read and understand these instructions before installing 

or operating.

SAFETY

IMPORTANT: Check HUD requirements before installing this 

fireplace.

These units are intended for installation in manufactured (mobile) 

homes. These units may also be installed in buildings of conventional 

construction including modular housing, providing all instructions 

provided herein are strictly adhered to. These fireplaces include a 

combustion air kit and bi-fold doors.
Before beginning installation of this fireplace, read these instructions 

through completely.

•  This INNOVATIVE HEARTH PRODUCTS, LLC (IHP) fireplace and 

its components are safe when installed according to this installa-

tion manual. Unless you use IHP components, which have been 

designed and tested for the fireplace system, you may cause a fire 

hazard.

•  The IHP warranty will be voided by and IHP disclaims any respon

-

sibility for the following actions.

a.

 Modification of the fireplace, components, doors, air inlet system 

and damper control.

b.

 Use of any component part not manufactured or approved by 

IHP in combination with an IHP fireplace system.

Proper installation is the most important step in ensuring safe and 

continuous operation of the fireplace. Consult the local building codes 

as to the particular requirements concerned with the installation of 
all factory built fireplaces.

TABLE OF CONTENTS

FOR YOUR SAFETY

•  Do not store or use gasoline or any other flammable vapors 

or liquids in the vicinity of this or any other appliance.

•  Due to high temperatures, the appliance should be located 

out of traffic and away from furniture and draperies.

•  Do not place clothing or other flammable materials on or near 

the appliance.

•  Never leave children unattended when a fire is burning in the 

fireplace.

     WARNING 

Improper installation, adjustment, alteration, service 

or maintenance can cause injury, property damage 

or loss of life. Refer to this manual for assistance or 

additional information. Consult a qualified installer 

or local distributor.

     CAUTION

The structural integrity of the mobile home floor and 

ceiling/roof must be maintained.

     WARNING 

Do not install a fireplace insert in this box unless the 

manufacturer's instructions with the insert specifically 

state this fireplace has been tested for use with the 

insert.

     WARNING 

Use solid wood or processed solid fuel fire logs only. 

Do not poke or stir the logs while they are burning. 

Use only firelogs that have been evaluated for the 

application in fireplace and refer to firelog warnings 

and caution markings on packaging prior to use.

Содержание MHWB36CB

Страница 1: ...ent free log heater see Accessories page 19 FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determ...

Страница 2: ...n sibility for the following actions a Modificationofthefireplace components doors airinletsystem and damper control b Use of any component part not manufactured or approved by IHP in combination with...

Страница 3: ...efluwithheadaches dizziness or nausea If you have these signs get fresh air at once Have the appliance inspected by a qualified service technician Some people are more affected by carbon monoxide than...

Страница 4: ...S THAN 14 356 mm TO PERPENDICULAR SIDEWALL OUTSIDE AIR LEFT SIDE ONLY GAS LINE KNOCK OUT ROUND TOP TERMINATION SQUARE CHASE TOP TERMINATION AIR KIT KNOCK OUT LEFT SIDE 13 7 8 353 mm 9 1 8 232 mm 3 4 1...

Страница 5: ...stem is 50 feet This measurement includes fireplace chimney sections and height of termination assembly at level of flue gas outlet see Figure 27 page 13 FRAMING 1 Frame opening for fireplace using di...

Страница 6: ...o Combustible Material 33 12 1 4 312 mm Ref 1 1 2 39 mm Max 6 153 mm Ref 6 153 mm Min 9 229 mm Min 12 305 mm Min 3 77 mm Nom Combustible Material Safe Zone For Projection of Combustible Materials Uppe...

Страница 7: ...ach outside air vent termination 6 Construct an 8 x 8 inside framing or opening on exterior wall 7 Install outside air vent termination in a location that would not eventually be obstructed by bushes...

Страница 8: ...Install the thimble from below a finished roof and ceiling assembly Push the thimble assembly tube section first up into an already prepared opening and secure open end of the thimble base to the fini...

Страница 9: ...boveceilinglevel firestopspacermustbeinstalled on the bottom side of the ceiling If an attic is above ceiling level firestop thimble must be installed on the bottom side of ceiling joist Figure 14 Not...

Страница 10: ...64 1 2 134 3 8 1 2 1 67 1 4 139 5 8 4 VENTING INSTALLATION Continued Figure 14 Installing Thimble Outer Pipe Thimble Cathedral Ceiling 14 Min Outer Pipe Of Chimney PENETRATING ROOF To maintain a 1 cle...

Страница 11: ...etrate inner stainless FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance be...

Страница 12: ...3 Places Secure with Screws RLT 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 23 Termination Overlap Shingles Top and Sides Flue Pipe of RLT 8DM Inside Inner...

Страница 13: ...92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figure 25 10 Foot Rule CHIMNEY SUPPORT BRACKET KIT CSK 8DM If exposed portion of chimney is greater than five feet above roofline support wires are recom...

Страница 14: ...g that the gas valve is on apply soap and water solution to all connections and joints Bubbles forming show a leak Correct all leaks at once DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPERAT...

Страница 15: ...in this fireplace Always keep fire back from doors and never allow flames to contact glass OPTIONAL GAS LINE INSTALLATION Continued FINISHING FIREPLACE Combustible materials such as wallboard gypsum...

Страница 16: ...yhole slot then pull down and forward to lock it in place see Figure 34 Vent damper must be locked in the full open position before operating fireplace Figure 33 Damper Handle Location Damper Handle W...

Страница 17: ...fireplace ready You can also visit our web site at Superiorfireplaces US com CAT NO MODEL DESCRIPTION BI FOLD GLASS DOORS F0972 BDB36 36 Standard Black Finish Included F0973 BDB36B 36 Standard Brushed...

Страница 18: ...600FS 8DM 1 1 Clearance Firestop Spacer ROOF FLASHING F0909 V6F 8DM Roof Flashing 0 to 6 12 Pitch 30 Base F0910 V12F 8DM Roof Flashing 6 12 to12 12 Pitch CHIMNEY SUPPORT BRACKET KIT Support Bracket Se...

Страница 19: ...ce Hood ADJUSTABLE FIRESTOP THIMBLE Not shown F2696 LB 97008A Adjustable Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Insulation and combustibles must not touch pipe Consult manual for clea...

Страница 20: ...Superiorfireplaces US com 900671 00_NC 20 PARTS WOOD BURNING FIREPLACE MODEL MHWB36CB 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 30 13 29 8 26 6 19 21...

Страница 21: ...Front Bottom Brick Liner 1 16 J6937 Blower Access Plate 1 17 J6895 Refractory Retainer 2 18 Top Insulation 1 19 Insulation Retainer 1 20 J6918 Top Standoff 4 21 J6893 Chimney Starter Collar 1 22 Door...

Страница 22: ...4 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock F0886 30E 8HT 30 Degree Hi Temp Offset and Return F0887 12S 8HT Hi Temp Chimney Suppor...

Страница 23: ...be subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with a...

Страница 24: ...aler name P900671 00 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and produc...

Отзывы: