24" (610 mm)Min.
24" (610 mm)Min.
18"
(458 mm)
Min. Typ.
Figure 24 - Multiple Chase Installation
VENTING INSTALLATION
Continued
Storm Collar Installation (SC1)
Place storm collar over pipe and slide down until it is snug against open
edge of flashing (see Figure 22). Use SC1 for all round terminations. Ap
-
ply waterproof caulk around perimeter of collar to provide a proper seal.
Terminations/Spark Arrestor
Fireplace system must be terminated with listed round top or chase
terminations. In any case, refer to installation instructions supplied
with termination. Terminations approved for this fireplace are RT-8DM
and RLT-8DM that can be used for flashing or chase and ET-8DM,
ETO-8DM, ETL-8DM and ETLO-8DM for chase style termination only.
Figure 17 shows an RLT-8DM round top termination.
Figure 22 - Storm Collar
Chimney Pipe
Waterproof Caulk
Storm Collar
Flashing
CHASE INSTALLATIONS
Instructions for chase installations are included with chase style ter-
mination chosen. In a multiple chase installation, be sure to provide
adequate distance between terminations to prevent smoke spillage
from one termination to another. We suggest that terminations be
separated at least 24", center to center and stacked at a vertical height
difference of 18" (see Figure 24).
Note:
If a decorative shroud is to be installed, contact manufacturer
for specifications.
Attach Bracket
Tabs to Outer Pipe
(3 Places) Secure
with Screws
RLT-8DM
Level of Flue
Gas Outlet
Caulk
Collar
Flashing
Underlap Shingles
Bottom Only
Figure 23 - Termination
Overlap Shingles
Top and Sides
Flue Pipe of RLT-8DM
Inside Inner Pipe of
Chimney
CAUTION
Do not seal openings on the rooftop flashing. Follow the
installation instructions provided with the termination
being used.
Terminations with 16" slip pipe sections are available. RTT-8DM and
RLTT-8DM are approved for flashing installations. When needed,
these adjustable terminations may be used in combination with pipe
assembly to achieve correct chimney height.
Note:
In the rare instance there is a problem with side driven rain or
wind or chimney is not drafting properly, an ADS-8DM (Anti-Draft
Shield) can be used with round terminations.
FLASHING INSTALLATION (V6F-8DM OR V12F-8DM)
Determine flashing to be used with roof opening chart. Slide flashing
over pipe until base is flat against roof. Replace as many shingles as
needed to cover exposed area and flashing base. Secure in position
by nailing through shingles (see Figure 21). DO NOT NAIL THROUGH
FLASHING CONE.
Installing Flashing on a Metal Roof
When installing flashing on a metal roof, it is required that putty tape
be used between flashing and roof. Flashing must be secured to roof
using #8 x 3/4" screws and then sealed with roof coating to prevent
leakage through screw holes. A roof coating must also be applied
around perimeter of flashing to provide a proper seal.
Figure 21 - Flashing Installation
Nail Only Outer
Perimeter of
Flashing
Storm Collar
Underlap Shingles at
Bottom
Flashing Cone
Overlap Shingles
Top and Sides Only