21
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation Instructions
901140-00, 01/2021
Innovative Hearth Products
DRT63ST-B Power-Vent Direct-Vent Fireplaces
L.
Install Firestop/Spacer at exterior wall.
Install SV4.5HF Firestop/Spacer, provided
with the power vent kit, over the opening at
the
exterior
side of the framing, long side
up, with the 3 inch spacer clearance at the
top as shown in
Figure 23
, and nail into
place.
(The Firestop/Spacer may also be installed
over the opening at the interior side of the
framing).
M.
Install the Power Vent termination.
For the last step, from outside the exterior
wall, slide the collars of the termination onto
the adaptor (the outer inside the outer and
the inner outside the inner) until the termi-
nation seats against the exterior wall sur-
face to which it will be attached. Orient the
housing of the termination with the arrow
pointed upwards. Secure the termination
to the exterior wall.
The termination must
not be recessed into the exterior wall or
siding
by more that the 1-1/4” (32 mm) as
shown in
Figure 24
.
Figure 23 - Installing Power Vent Horizontal Termination
7"
(178)
5-1/8"
(130 mm)
12-1/8"
(308 mm)
3"
(77 mm)
1"
(26 mm)
10-1/2"
(267 mm)
The Power Vent termination has been
designed to perform in a wide range of
weather conditions. Our terminations meet
or exceed industry standards.
When selecting the location of your ter-
mination, do not place the termination
where water from eaves and adjoining
roof lines may create a heavy flow of
cascading water onto the terminations. If
the termination must be placed where the
possibility of cascading water exists, it is
the responsibility of the builder to direct
the water away from the termination cap
by using gutters or other means.
Take care to carefully follow the Installation
Instructions for the termination, including
the use of silicone caulking where required.
To help minimize water infiltration it is recom-
mended that the Firestop/Spacer (SV4.5HF) be
installed on the exterior side of the wall.
Power Vent
Termination
NOTE: Centerline of Vent Piping is
NOT the Same as the Centerline of
the Frame Opening.
Base of Appliance
6" to 48" Vent Section, Telescopic vent
section, Elbow or Appliance Collar
Termination
Adaptor
SV4.5RCH
IMPORTANT: The vent termination is hot
while in operation and for a period of time
following the use of the fireplace. Young
children should be carefully supervised
when they are in the same area as a hot
termination.
See Table 8 as an aid in venting component
selection for a particular range of exterior
wall thicknesses.
Figure 24
Last Vent Section.
Use Telescopic Vent
Section (SV4.5LA),
If Necessary
*Use silicone caulking to
seal the top and sides of
the termination, up to the
underlayment, stucco, or
masonry wall surface.
Interior Surface of
Finished Wall
Maximum Extent of Vent Run
Sections Relative to Exterior
Surface of Framing
Siding
Power Vent
Termination
Power Vent
Termination
Termination
Adaptor
SV4.5RCH
Exterior Surface of Siding
Maximum wall thickness
9-1/4 in.(235 mm)**
6 in. to 9-1/4 in.
(152 to 235 mm)**
Exterior Surface of Framing
1-1/4" Maximum Recess
of the Square Termina-
tion into Exterior Finish-
ing Material
Caulk*
Caulk*
Stucco
**For thicknesses greater
than 9-1/4”, see Table 8
Venting Connection and Exterior Wall Recessing
of the Power Vent Horizontal Termination
Venting Components Required for Various Exterior
Wall Thicknesses, When Using The Power Vent Termination
Vent Components Required
Exterior Wall Thickness - inches (mm)
Termination Kit Only
6 to 9-1/4 (152 to 235)
Termination Kit and 6" Vent Section (SV4.5L6)
10-3/4 to 14 (273 to 356)
Termination Kit and 12" Vent Section (SV4.5L12)
16-3/4 to 20 (426 to 508)
Termination Kit and Telescopic Section
(SV4.5LA) and 6” vent section (SV4.5L6)
11-3/4 to 20 (299 to 508)
Table 8
See
Figure 10
on
Page 12
for Minimum
Distance to Base of Appliance