2 x 4
Top of
Fireplace
11
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 9 - Side Wall Clearances
Figure 8 - Combustible Mantel Clearances
3" (77 mm) above any horizontal/inclined vent component.
See
Step 1 ("FRAMING")
on
Page 12
for clearance requirements to
the nailing flanges on each side of the unit and any adjacent screw
heads.
The appliance should be mounted on a fully supported base extending
the full width and depth of the unit. The appliance may be located on
or near conventional construction materials; however, if installed on
combustible materials, such as carpeting, vinyl tile, etc., a metal or wood
barrier covering the entire bottom surface must be used.
Min. Height of Combustible Enclosure
To provide for the lowest possible combustible enclosure (or shelf)
surface, the venting should be routed in a way to minimize obstructions
to the space above the appliance. Do not insulate the space between the
appliance and the area above it (see
Figure 7
).
Wall Finishes / Surrounds / Mantels
NOTE:
Combustible wall finish materials and/or surround materials must
not be allowed to encroach the area defined by the appliance front faces
(black sheet metal). Never allow combustible materials to be positioned
in front of or overlapping the appliance face. See
Pages 32 and 33
.
Non-combustible materials, such as surrounds and other appliance trim,
may be installed on the appliance front face only if they do NOT cover
any portion of the removable glass panel.
Vertical installation clearances to combustible mantels vary according
to the depth of the mantel. See
Figure 8
. Mantels constructed of non-
combustible materials may be installed at any height above the appliance
opening.
NOTE:
To avoid heat-related finish damage, we recommend the use of
high-temperature paint (rated 175°F or higher) on the underside of the
mantel.
7 (178)
2
(51)
4
(102)
6
(152)
8
(203)
10
(254)
12
(305)
9 (229)
13 (330)
17 (432)
15 (381)
11 (279)
Side View
Inches
(millimeters)
Mantel Depth
Minimum Distance to Unprotected Side Wall
Top of Appliance
Distance from top of appliance
to bottom of mantel
MINIMUM CLEARANCES TO COMBUSTIBLES
Appliance and Vent Clearances
The appliance is approved with zero clearance to combustible materials
on both sides (as detailed in
Table 5)
, with the following exceptions:
• When the unit is installed with one side flush with a wall, the wall on the
other side of the unit must not extend beyond the front edge of the unit.
• In addition, when the unit is recessed, the side walls surrounding the
unit must not extend beyond the front edge of the unit (see
Figure 2
on Page 7
)
.
Figure 7 - Min. Height of Combustible Enclosure
Min. 2 ft vertical
vent section
and one 90-degree
elbow required
Combustible
Enclosure (or Shelf)
Min. 3"
(77 mm)
Min. 90"
(2287 mm)
Indoor/
Outdoor
Min. 91-1/2"
(2324 mm)
Indoor/Outdoor
Combustible materials
are allowed in
gray
“safe
zone” illustrated here.
Combustible walls are
shown in
black
.
Protected wall is shown
in
white
.
Combustible material
may project beyond
the side of the fireplace
opening if it is within
the
gray
"safe zone"
illustrated here.
0.5"
(13 mm)
5 in
(127 mm)
8.25"
(209 mm)
14"
(356 mm)
12 in
(305 mm)
17 in
(432 mm)
Top View of Fireplace
45°
Protected wall
shown in white
Gray area
is “safe
zone”
At 14" minimum
side wall clearance,
a combustible
wall can project
to any length.
At 8-1/4" side
wall clearance,
a combustible
wall can project
12" maximum.
~
~
Do NOT insulate space between
appliance and area above it.
MINIMUM CLEARANCES TO COMBUSTIBLES
Back / Sides
0" (0 mm) Spacers
Top Spacers
0" (0 mm)
Floor
0" (0 mm)
Unit Bottom to Ceiling
72" (1829 mm)
Vertical Vent Pipe
1" (26 mm)
Horizontal Vent Pipe
Top: 3" (77 mm)
Sides: 1" (26 mm)
Bottom: 1" (26 mm)
SERVICE CLEARANCES
Front
3 ft (0.9 m)
Table 5
General Information
901140-00, 01/2021
Innovative Hearth Products
DRT63ST-B Power-Vent Direct-Vent Fireplaces