Installation Instructions

900358-00, 01/2018

Innovative Hearth Products
DRT63STTYN Power-Vent Direct-Vent Fireplaces

Figure 18

Align the dimple (four places) of the 

upper vent section with the opening 

of the locking incline channel on 

the lower vent section or appliance 

collar.  Twist vent component clock-

wise to engage and seal until arrow 

and dimple align.

Dimple

Locking Incline 

Channel

Connected Vent 

Sections

Arrow

Arrow

Adaptor on Appliance Collar 

or Vent Section

E.

 

Support the vertical vent run sections.

NOTE: 

Proper venting support is very important. 

The weight of the vent must not be supported 

by the fireplace in any degree.

 

Support the vertical portion of the venting 

system every 8 feet (2.4 m) above the fireplace 

vent outlet. One method of support is by utiliz-

ing field provided support straps (conventional 

plumber's tape). Secure the plumber's tape to 

the framing members with nails or screws.

 

Strap the tape around the vent, securing the 

ends of the tape to the framing. If desired, 

sheet metal screws #6 x 1/2" length may be 

used to secure the support straps to the vent 

pipe (see 

Figure 19

)

.

F. Change vent direction to horizontal/inclined 

run. 

At transition from or to a horizontal/inclined 

run, install the SV4.5 E45 and SV4.5 E90 elbows 

in the same manner as the straight vent sec-

tions.  The elbows feature a twist section to 

allow them to be routed about the center axis 

of their initial collar section to align with the 

required direction of the next vent run element. 

Twist elbow sections in a clockwise direction 

only so as to avoid the possibility of unlocking 

any of the previously connected vent sections 

(see 

Figures 18 and 20

)

.

B.

 

Attach adaptor (with probe) to appli-

ance collar. Secure Vent

®

 SV4.5 direct-vent 

system components are unitized concentric 

pipe components featuring positive twist lock 

connections (

see 

Figure 18

)

.

All of the appliances covered in this document 

are fitted with collars having locking inclined 

channels. The dimpled end of the adaptor fits 

over the appliance collar to create the positive 

twist lock connection.

The unitized design of the 

Secure Vent

 com-

ponents will engage and seal both the inner 

and outer pipe  without the need for sealant or 

screws.  If desired a #6 x 1/2" screw may be 

used at the joint, but it is not required as the 

pipe will securely lock when twisted.

C. Attach vent components to each other.

 Other 

vent sections may be added to the previously 

installed section in accordance with the require-

ments shown in 

Figures 21 and 22 on Page 19

.

To add another vent component to a length of 

vent run, align the dimpled end over the inclined 

channel end of the previously installed section, 

adjusting the radial alignment until the four 

locking dimples are aligned with the inlets of 

the four incline channels of the previous section. 
Push the vent component against the previ-

ous section until it fully engages, then twist 

the component clockwise running the dimples 

down and along the incline channels until they 

seat at the end of the channels. 

This seating 

position is indicated by the alignment of the 

arrow and dimple as shown in

 

Figure 18.

D.

 

Install firestop/spacer at ceiling.

 When 

using Secure Vent, use SV4.5VF firestop/spacer 

at ceiling joists. If there is living space above 

the ceiling level, the firestop/spacer must be 

installed on the bottom side of the ceiling. If 

attic space is above the ceiling, the firestop/

spacer must be installed on the top side of 

the joist. Route the vent sections through the 

framed opening and secure the firestop/spacer 

with 8d nails or other appropriate fasteners at 

each corner. 

 Remember to maintain 1" (26 

mm) clearance to combustibles, framing 

members, and attic or ceiling insulation 

when running vertical chimney sections.  At-

tic insulation shield (H3907) is required and 

may be used to help maintain the clearances 

indicated here. See installation accessories 

on 

Page 34

.  The gap between the vent pipe 

and a vertical firestop can be sealed with 

non-combustible caulking.

To attach a vent component to the adaptor on 

appliance collar, align the dimpled end over the 

adaptor collar, adjusting the radial alignment 

until the four locking dimples are aligned with the 

inlet of the four inclined channels on the collar 

(

refer to 

Figure 18

).

 Push the vent component 

against the collar until it fully engages, then twist 

the component clockwise, running the dimples 

down and along the incline channels until they 

seat at the end of the channels.  

G.

 

Continue installation of horizontal/inclined  

sections. 

Continue with the installation of the 

straight vent sections in horizontal/inclined run 

as described in 

Step C.

 Install support straps 

every 3' (914 mm) along horizontal/inclined 

vent runs using conventional plumber’s tape 

(

see Page 19, Figure 21

)

.

Figure 19

It is important to maintain the required clear-

ances to combustibles: 1" (26 mm) at all sides 

for all vertical runs; and 3" (77 mm) at the 

top, 1" (26 mm) at sides, and 1" (26 mm) at 

the bottom for all horizontal/inclined runs.

 

NOTICE: 

It is important to install 

horizontal runs on a steady, (i.e., no 

“dips”), slightly positive incline of 

approximately 1/4" rise-per-foot (20 

millimeters rise-per-meter) horizontal, 

in a direction away from the fireplace. 

(Slightly smaller rise-per-foot run ratios 

are acceptable.) Use a carpenter’s level 

to measure from a constant surface, and 

adjust support straps as necessary.

Blocking

Support Straps

(plumber’s tape)

Max. 

8 ft (2.4 m)

Min. 0" (0 mm)  

clearance  

to spacers 

A.

 

Frame ceiling opening. 

Use a plumb line 

from the ceiling above the appliance to locate 

center of the vertical run. Cut and/or frame an 

opening, 10-1/2" x 10-1/2"  (267 mm x 267 

mm) inside dimensions, about this center mark 

(

Figure 17

)

.

Figure 17 - Ceiling Opening Framing

Min. 10-1/2" 

   (267 mm)

Ceiling 
Framing

Plumb Bob

Min. 10-1/2" 

   (267 mm)

7-5/8”

(194 mm)

4-13/16 

(122 mm)

Swivel Joint

(360° swivel)

SV4.5E45

45° Elbow)

Swivel Joint

(360° swivel)

SV4.5E90

90° Elbow)

(206 mm)

8-1/8"

Figure 20 

Содержание DRT63

Страница 1: ...re fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent trea...

Страница 2: ...UN ENFANT DE TOUCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidr...

Страница 4: ...tits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes GENERAL INFORMATION PACKAGING Fireplace Components 1 Literature Kit this manual 1 Remote Control K...

Страница 5: ...of the control system and any gas control which have been under water Ne pas utiliser cet appareil s il a t plong m me partiellement dans l eau Appeler un technicien qualifi pour inspecter l appareil...

Страница 6: ...des latest edition Gas Supply Pressure Requirements continued from previous page Test gauge connections are provided on the front of the electronic gas control valve identi fied IN for the inlet and O...

Страница 7: ...ON For cold climate installations seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room If the floor is above ground level it is especially impor...

Страница 8: ...f vent General Information 900358 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces Figure 3 Horizontal Power Vent Termination Clearances to Combustibles For recess al...

Страница 9: ...tu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fireplaces 10 000 Btu h 3 kW 12 300 mm for fireplaces 10 000 Btu h 3 kW K Clearance to a mechanical air supply inlet 36 910 mm above...

Страница 10: ...fireplace and may butt against the front face of the fireplace see Figures 5 and 6 Also note the following Combustible material may project beyond the sides of the fireplace opening as long as it is...

Страница 11: ...r on the underside of the mantel 7 178 2 51 4 102 6 152 8 203 10 254 12 305 9 229 13 330 17 432 15 381 11 279 Side View Inches millimeters Mantel Depth Minimum Distance to Unprotected Side Wall Top of...

Страница 12: ...may be in direct contact with the nailing flanges and may be located closer than 1 2 inch from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to the ex...

Страница 13: ...ireplace must be installed on the indoor side Dimension B is from fireplace base to top framing member Dimension C is from fireplace base to centerline of horizontal vent pipe Minimum vent framing Ada...

Страница 14: ...nner 7 1 2 Outer Adaptor Probe assembly cat no H8313 required to transition from fireplace vent collar to vent pipe 50 1 2 1283 29 5 8 753 12 3 8 314 5 1 8 130 41 1 2 1054 33 3 4 857 34 3 4 883 13 1 8...

Страница 15: ...e Side of Fireplace Framing 19 1 2 495 mm Right Side Front Corner Of Fire place Framing Step 2 ROUTE GAS LINE NOTICE For indoor outdoor installations the CONTROL SIDE of the fireplace must be installe...

Страница 16: ...semblyupside down as shown 2 Remove the four screws securing the vent restrictor in place Lift out the vent restrictor 3 Install the appropriate vent restrictor using the four screws previously remove...

Страница 17: ...0 1 1 0 1 1 5 8 1 4 5 7 8 4 3 0 0 0 0 9 9 5 6 4 5 7 8 3 0 0 0 0 0 1 0 1 5 5 7 4 5 2 6 9 3 0 1 0 0 0 1 1 1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2...

Страница 18: ...i ous section until it fully engages then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels This seating position is indi...

Страница 19: ...ime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Adaptor Probe Assembly Required NOTICE...

Страница 20: ...Install support straps every 3 feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape See Figure 21 on Page 19 HORIZONTAL OUTSIDE WALL TERMINATION SYSTEM See Figures 21 an...

Страница 21: ...including theuseofsiliconecaulkingwhererequired To help minimize water infiltration it isrecom mended that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall Power Vent Termina...

Страница 22: ...e electrical wiring refer to Figure 25 Standard Instruction For use when access to the termination is difficult because of height or other reasons Locate a locally procured electrical junction box wit...

Страница 23: ...sen the strain relief on the termination shown in Figure 28 Pull the pigtail in and shorten it to fit within the junction box cover Route 14 gauge AWG grounded Romex wiring not provided from fireplace...

Страница 24: ...tall ing the glass door frame Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass with any materials other than those provided by the appliance manufacturer The...

Страница 25: ...r tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Reinstall the access plate ma...

Страница 26: ...l Side top view of burner shown Place glowing ember material in circled areas ONLY Do NOT place glowing ember material over main flame gas ports To prevent flame impingement and soot do not use more e...

Страница 27: ...r Log B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 9 LOG SET Item Description Item Description A Log Center D Lo...

Страница 28: ...e finger Rest the other end of the log on the Landing on Center Log A Figure 46 9 10 See Figure 46 Place hole on underside of Top Left Log E over pin on Center Log A 9 9 Place groove on underside of T...

Страница 29: ...Install the new approved factory barrier with flatsideofbarriertowardfirebox ifappropriate 2 Remove the modesty panel from the top flange of the glass door by firmly pulling up on it with both hands...

Страница 30: ...er flame appearance is a flame that is blue at the base and becomes yellowish orange in the body of the flame When the appliance is first lit the entire flame may be blue and will graduallyturnyellowi...

Страница 31: ...le Finished Wall Materials Wall Stud Top of Door Frame FIREPLACE side view Top of Appliance Spacers Insulation is NOT ALLOWED in clearance zones around vent components Keep this area free from combust...

Страница 32: ...front lip of each Mounting Bracket and then align the holes Step 5 Slide the openings in the bottom edge of the Safety Guard over the Spring Nut Clips Step 6 Align the holes in the top of the Outdoor...

Страница 33: ...e ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propr...

Страница 34: ...with a storm collar H5816 750 247M SV4 5 TWSK Through Wall Shield Kit used to shield direct vent pipe from blown insulation Ref doc P N 750247M 96K93 SV4 5SU Support Strap 96K92 SV4 5SP Support Plate...

Страница 35: ...H7952 Liquid Propane to Natural Gas Conversion Kit Table 10 Gas Conversion Kit Instructions P N 506020 44 GAS CONVERSION KITS Gas conversion kits are available to adapt your appliance from the use of...

Страница 36: ...eunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison...

Страница 37: ...eur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 2 Rep rez la t l commande et nettoyez la soigneuse ment pour liminer la po...

Страница 38: ...CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas...

Страница 39: ...r is required to operate these units These models come standard with a remotely modulated gas valve The included transmitter remotely controls flame appearance and heat output manual gas valve adjustm...

Страница 40: ...m hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraient tresurveill s troitementlorsqu ilssetrou ventdanslam mepi cequel appareil Lestoutpetits lesjeunesenfants ou les adultes peuvent subir des br lure...

Страница 41: ...rner turns on A single beep from the Receiver will confirm reception of the command Turn OFF the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room t...

Страница 42: ...ing the three position slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Figu...

Страница 43: ...e combustion Inspect Wiring Refer to wiring diagram on Page 49 CAUTION Label all wires prior to disconnec tion when servicing controls Wiring errors cancauseimproperanddangerousoperation Verify proper...

Страница 44: ...the top of the door held away from the fireplace see Figure 63 c Lower the bottom of the door assembly onto the bottom door track engaging and centering it in the base channel and then gently swing th...

Страница 45: ...soot do not use more ember material than necessary c For best glowing effect replace ember material annually NOTE Use only catalog number H8312 Platinum Glowing Embers with this fireplace Control Sid...

Страница 46: ...B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 5 LOG SET Item Description Item Description A Log Center D Log Top...

Страница 47: ...the other end of the log on the Landing on Center Log A Figure 73 10 See Figure 19 Place hole on underside of Top Left Log E over pin on Center Log A 9 Place groove on underside of Top Right Log D ove...

Страница 48: ...ew more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation...

Страница 49: ...TION Model Number_________________________________________________________ Serial Number_________________________________________________________ Date Installed _______________________________________...

Страница 50: ...Andiron Kits Cat No Model Description H2227 AKM LSM Andirons Mission H2228 AKC LSM Andirons Classic Touch Up Paint Kit Repair of minor scratches and discoloration of the appliances black painted surfa...

Страница 51: ...e beauty of the fireplace Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40 2 Dual Arch Screen Classic Screen Kits Cat No Model Description H5052 SK LSM40 2 Classic Screen Kit Outdoor Ki...

Страница 52: ...e 9 Slide the switch on the receiver to REMOTE 10 Press ON OFF button on transmitter to ON 11 Set thermostat on remote control to desired setting 12 If the appliance will not operate follow the instru...

Страница 53: ...suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l a...

Страница 54: ...essive condensation can cause corrosion of caps pipe and fittings excessive condensation can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold...

Страница 55: ...s supply and gas shutoff valves call a service technician if required B Air in gas line Call a service technician C Loose wires to valve Check control compartment for any obvious loose wiring call a s...

Страница 56: ...e Hose From The Blower To The Pressure Switch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Spark Electrode Attached Or A...

Страница 57: ...35 Receiver Kit H7277 1 36 Receiver Cable Harness H8008 1 37 AC DC Power Adaptor H8006 1 38 Transmitter Kit H7275 1 39 Ground Wire H7278 1 44 Power Vent Module H7367 1 Item No Description Cat No Qty...

Страница 58: ...8 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces 22 REPLACEMENT PARTS ILLUSTRATION Circled numbers correspond to Replacement Parts List on previous page 1 2 4 18 25...

Страница 59: ...Ring Terminal 10 2 7 H7384 Insulated 1 4 Male Terminal 4 8 H7371 Hose Clamp 11 32 2 15 H7372 Base Assembly Power Vent 1 16 H7378 Kicker Assembly 1 POWER VENT REPLACEMENT PARTS Item Part Number Descri...

Страница 60: ..._____________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________________...

Страница 61: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 62: ...ial number Date fireplace was Installed Type of gas fireplace uses Dealer name Printed in U S A 2014 Innovative Hearth Products P N 900358 00 Rev C 01 2018 1769 East Lawrence Street Russellville AL 35...

Отзывы: