 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, fi rebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 

against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 

Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 

replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 

the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The product body, fi rebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 

from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 

natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 

and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 

(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 

venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 

manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 

any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 

after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 

particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание DRT63

Страница 1: ...re fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent trea...

Страница 2: ...UN ENFANT DE TOUCHER LA VITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le...

Страница 3: ...toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidr...

Страница 4: ...tits les jeunes enfants et toute autre personne risque d avoir acc s la pi ce et aux surfaces chaudes GENERAL INFORMATION PACKAGING Fireplace Components 1 Literature Kit this manual 1 Remote Control K...

Страница 5: ...of the control system and any gas control which have been under water Ne pas utiliser cet appareil s il a t plong m me partiellement dans l eau Appeler un technicien qualifi pour inspecter l appareil...

Страница 6: ...des latest edition Gas Supply Pressure Requirements continued from previous page Test gauge connections are provided on the front of the electronic gas control valve identi fied IN for the inlet and O...

Страница 7: ...ON For cold climate installations seal all cracks around the appliance with noncombustible material and wherever cold air could enter the room If the floor is above ground level it is especially impor...

Страница 8: ...f vent General Information 900358 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces Figure 3 Horizontal Power Vent Termination Clearances to Combustibles For recess al...

Страница 9: ...tu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm for fireplaces 10 000 Btu h 3 kW 12 300 mm for fireplaces 10 000 Btu h 3 kW K Clearance to a mechanical air supply inlet 36 910 mm above...

Страница 10: ...fireplace and may butt against the front face of the fireplace see Figures 5 and 6 Also note the following Combustible material may project beyond the sides of the fireplace opening as long as it is...

Страница 11: ...r on the underside of the mantel 7 178 2 51 4 102 6 152 8 203 10 254 12 305 9 229 13 330 17 432 15 381 11 279 Side View Inches millimeters Mantel Depth Minimum Distance to Unprotected Side Wall Top of...

Страница 12: ...may be in direct contact with the nailing flanges and may be located closer than 1 2 inch from screw heads and the firebox wrapper in areas adjacent to the nailing flanges Frame the opening to the ex...

Страница 13: ...ireplace must be installed on the indoor side Dimension B is from fireplace base to top framing member Dimension C is from fireplace base to centerline of horizontal vent pipe Minimum vent framing Ada...

Страница 14: ...nner 7 1 2 Outer Adaptor Probe assembly cat no H8313 required to transition from fireplace vent collar to vent pipe 50 1 2 1283 29 5 8 753 12 3 8 314 5 1 8 130 41 1 2 1054 33 3 4 857 34 3 4 883 13 1 8...

Страница 15: ...e Side of Fireplace Framing 19 1 2 495 mm Right Side Front Corner Of Fire place Framing Step 2 ROUTE GAS LINE NOTICE For indoor outdoor installations the CONTROL SIDE of the fireplace must be installe...

Страница 16: ...semblyupside down as shown 2 Remove the four screws securing the vent restrictor in place Lift out the vent restrictor 3 Install the appropriate vent restrictor using the four screws previously remove...

Страница 17: ...0 1 1 0 1 1 5 8 1 4 5 7 8 4 3 0 0 0 0 9 9 5 6 4 5 7 8 3 0 0 0 0 0 1 0 1 5 5 7 4 5 2 6 9 3 0 1 0 0 0 1 1 1 0 8 4 0 4 1 1 0 0 0 1 1 1 2 9 4 1 4 1 0 1 0 0 1 2 1 5 9 9 4 5 2 6 1 4 0 0 0 1 0 1 1 1 4 0 5 2...

Страница 18: ...i ous section until it fully engages then twist the component clockwise running the dimples down and along the incline channels until they seat at the end of the channels This seating position is indi...

Страница 19: ...ime vent pipe passes through a combustible floor or ceiling SV4 5HF Secure Vent firestop spacer must be used anytime vent pipe passes through a combustible wall Adaptor Probe Assembly Required NOTICE...

Страница 20: ...Install support straps every 3 feet 1914 mm along horizontal inclined vent runs using conventional plumber s tape See Figure 21 on Page 19 HORIZONTAL OUTSIDE WALL TERMINATION SYSTEM See Figures 21 an...

Страница 21: ...including theuseofsiliconecaulkingwhererequired To help minimize water infiltration it isrecom mended that the Firestop Spacer SV4 5HF be installed on the exterior side of the wall Power Vent Termina...

Страница 22: ...e electrical wiring refer to Figure 25 Standard Instruction For use when access to the termination is difficult because of height or other reasons Locate a locally procured electrical junction box wit...

Страница 23: ...sen the strain relief on the termination shown in Figure 28 Pull the pigtail in and shorten it to fit within the junction box cover Route 14 gauge AWG grounded Romex wiring not provided from fireplace...

Страница 24: ...tall ing the glass door frame Donotattempttosubstitutethe materials used on this door or replace cracked or broken glass with any materials other than those provided by the appliance manufacturer The...

Страница 25: ...r tighten or refasten the leaking connection then retest as described above C When the gas lines are tested and leak free be sure to rinse off the leak testing solution D Reinstall the access plate ma...

Страница 26: ...l Side top view of burner shown Place glowing ember material in circled areas ONLY Do NOT place glowing ember material over main flame gas ports To prevent flame impingement and soot do not use more e...

Страница 27: ...r Log B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 9 LOG SET Item Description Item Description A Log Center D Lo...

Страница 28: ...e finger Rest the other end of the log on the Landing on Center Log A Figure 46 9 10 See Figure 46 Place hole on underside of Top Left Log E over pin on Center Log A 9 9 Place groove on underside of T...

Страница 29: ...Install the new approved factory barrier with flatsideofbarriertowardfirebox ifappropriate 2 Remove the modesty panel from the top flange of the glass door by firmly pulling up on it with both hands...

Страница 30: ...er flame appearance is a flame that is blue at the base and becomes yellowish orange in the body of the flame When the appliance is first lit the entire flame may be blue and will graduallyturnyellowi...

Страница 31: ...le Finished Wall Materials Wall Stud Top of Door Frame FIREPLACE side view Top of Appliance Spacers Insulation is NOT ALLOWED in clearance zones around vent components Keep this area free from combust...

Страница 32: ...front lip of each Mounting Bracket and then align the holes Step 5 Slide the openings in the bottom edge of the Safety Guard over the Spring Nut Clips Step 6 Align the holes in the top of the Outdoor...

Страница 33: ...e ment pour liminer la poussi re et les traces degraisseoud huile Collezl tiquettesurlebo tier de la t l commande Figure B Choisissez la langue qui est principalement parl e dans la r sidence du propr...

Страница 34: ...with a storm collar H5816 750 247M SV4 5 TWSK Through Wall Shield Kit used to shield direct vent pipe from blown insulation Ref doc P N 750247M 96K93 SV4 5SU Support Strap 96K92 SV4 5SP Support Plate...

Страница 35: ...H7952 Liquid Propane to Natural Gas Conversion Kit Table 10 Gas Conversion Kit Instructions P N 506020 44 GAS CONVERSION KITS Gas conversion kits are available to adapt your appliance from the use of...

Страница 36: ...eunes enfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison...

Страница 37: ...eur mural qui contr le le foyer Figure A Choisissez la langue qui est principalement parl e dans la r sidence du propri taire 2 Rep rez la t l commande et nettoyez la soigneuse ment pour liminer la po...

Страница 38: ...CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Turn off the gas...

Страница 39: ...r is required to operate these units These models come standard with a remotely modulated gas valve The included transmitter remotely controls flame appearance and heat output manual gas valve adjustm...

Страница 40: ...m hot surfaces AVERTISSEMENT Lesjeunesenfantsdevraient tresurveill s troitementlorsqu ilssetrou ventdanslam mepi cequel appareil Lestoutpetits lesjeunesenfants ou les adultes peuvent subir des br lure...

Страница 41: ...rner turns on A single beep from the Receiver will confirm reception of the command Turn OFF the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room t...

Страница 42: ...ing the three position slider switch to the ON position This will bypass the remote control feature of the system and the appliance main burner will come on if the gas valve is in the ON position Figu...

Страница 43: ...e combustion Inspect Wiring Refer to wiring diagram on Page 49 CAUTION Label all wires prior to disconnec tion when servicing controls Wiring errors cancauseimproperanddangerousoperation Verify proper...

Страница 44: ...the top of the door held away from the fireplace see Figure 63 c Lower the bottom of the door assembly onto the bottom door track engaging and centering it in the base channel and then gently swing th...

Страница 45: ...soot do not use more ember material than necessary c For best glowing effect replace ember material annually NOTE Use only catalog number H8312 Platinum Glowing Embers with this fireplace Control Sid...

Страница 46: ...B FIREBOX ACCESSORIES PARTS Cat No Model Description H8312 PGE Bag of Platinum Glowing Embers 80L42 FDVS Bag of Volcanic Stone Table 5 LOG SET Item Description Item Description A Log Center D Log Top...

Страница 47: ...the other end of the log on the Landing on Center Log A Figure 73 10 See Figure 19 Place hole on underside of Top Left Log E over pin on Center Log A 9 Place groove on underside of Top Right Log D ove...

Страница 48: ...ew more minutes to ensure that the flame normalizes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation...

Страница 49: ...TION Model Number_________________________________________________________ Serial Number_________________________________________________________ Date Installed _______________________________________...

Страница 50: ...Andiron Kits Cat No Model Description H2227 AKM LSM Andirons Mission H2228 AKC LSM Andirons Classic Touch Up Paint Kit Repair of minor scratches and discoloration of the appliances black painted surfa...

Страница 51: ...e beauty of the fireplace Dual Arch Screen Kits Cat No Model Description H5051 DASK LSM40 2 Dual Arch Screen Classic Screen Kits Cat No Model Description H5052 SK LSM40 2 Classic Screen Kit Outdoor Ki...

Страница 52: ...e 9 Slide the switch on the receiver to REMOTE 10 Press ON OFF button on transmitter to ON 11 Set thermostat on remote control to desired setting 12 If the appliance will not operate follow the instru...

Страница 53: ...suivante 8 Mettez l appareil sous tension 9 Placez l interrupteur du r cepteur en position REMOTE 10 Appuyez sur le bouton ON OFF pour s lectionner ON 11 Ajustez le thermostat sur la t l commande l a...

Страница 54: ...essive condensation can cause corrosion of caps pipe and fittings excessive condensation can be caused by long lateral runs too many elbows and or exterior portions of the system being exposed to cold...

Страница 55: ...s supply and gas shutoff valves call a service technician if required B Air in gas line Call a service technician C Loose wires to valve Check control compartment for any obvious loose wiring call a s...

Страница 56: ...e Hose From The Blower To The Pressure Switch Are the Hose Connections Loose Is The Hose Cracked Replace Pressure Switch Replace Control Module Yes Yes Is The Lead To The Spark Electrode Attached Or A...

Страница 57: ...35 Receiver Kit H7277 1 36 Receiver Cable Harness H8008 1 37 AC DC Power Adaptor H8006 1 38 Transmitter Kit H7275 1 39 Ground Wire H7278 1 44 Power Vent Module H7367 1 Item No Description Cat No Qty...

Страница 58: ...8 00 01 2018 Innovative Hearth Products DRT63STTYN Power Vent Direct Vent Fireplaces 22 REPLACEMENT PARTS ILLUSTRATION Circled numbers correspond to Replacement Parts List on previous page 1 2 4 18 25...

Страница 59: ...Ring Terminal 10 2 7 H7384 Insulated 1 4 Male Terminal 4 8 H7371 Hose Clamp 11 32 2 15 H7372 Base Assembly Power Vent 1 16 H7378 Kicker Assembly 1 POWER VENT REPLACEMENT PARTS Item Part Number Descri...

Страница 60: ..._____________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________________...

Страница 61: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 62: ...ial number Date fireplace was Installed Type of gas fireplace uses Dealer name Printed in U S A 2014 Innovative Hearth Products P N 900358 00 Rev C 01 2018 1769 East Lawrence Street Russellville AL 35...