WIRING DIAGRAM

 

Robertshaw 

MODE

SP745 IGNITION CONTRO

STEP DOWN 

TRANSFORMER 

PV 

GND 

PV/MV 

TR
 

MV 

TH
 

VENT SAFETY 

SHUTOFF SWITCH 

MANUAL 

DAMPER 

SWITCH 

IGN

 

EV2 

SUPPLY 

INCOMING 
MAIN GAS 

EV1 

TO  

GAS LINE 

 BURNER 

24V AC 

120V AC 

120V AC 

INCOMING 

OR BREAKER) 

(FUSE BOX 

OFF 

ON

 

(NOT SUPPLIED)

WALL SWITCH 

GREEN

 

BLACK 

WHITE

 

120v, 60Hz, 0.7A 

ELECTRICAL RATING: 

BLACK 

WHITE 

GREEN 

OPTIONAL 
REMOTE 

CONTROL 

Pilot Burner

Pilot Gas Line

 WARNING: Electrical Grounding Instructions - This appliance is equipped with a three-prong 

(grounding) plug for your protection against shock hazard and should be plugged directly into a 

properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.

Figure 41 - Wiring Diagram

MANUALLY-RESET SAFETY LIMIT SWITCH

This appliance is equipped with a manually-reset blocked flue safety 

limit switch. Refer to

 Figure 42

 for its location. If, during appliance 

operation, the flame goes out (independently of the burner on/off wall 

switch), it may be due to the operation of this safety limit switch. First 

allow the appliance to cool, then reset the safety switch by pressing 

the red reset button on the back of the switch.

Figure 42 - Blocked Flue Safety Switch, Removal and Reinstallation

Figure 43- Blocked Flue Safety Switch, Red Reset Button

To access the blocked flue safety limit switch, refer to 

Figure 42

:

1.  To access the blocked flue safety switch, remove the two (2) 

phillips head screws 

(shown in Figure 42)

 and pull out switch.

2.  Press the red reset button on the switch 

(see Figure 43).

3.  Reinstall switch.

The appliance should then relight and remain lit. If this does not oc-

cur, turn off the appliance and call a qualified service technician.

Blocked Flue Safety 

Limit Switch

Red Reset Button

Blocked Flue Safety 

Limit Switch

Use Phillips Head Tool

Содержание BRT4036TEN-B

Страница 1: ...ppelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installatione...

Страница 2: ...d its installation complies with State and Local Codes and in the absence of these codes complies with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code C...

Страница 3: ...depth of the fireplace 17 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 18 Do not operate fire...

Страница 4: ...nner other than instructed in this manual D Burning of anything other than the type of gas approved for use in this gas appliance UNPACKING The following items are packed inside the firebox Remove bef...

Страница 5: ...INSTALLATION FLUSH INSTALLATION WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need a building pe...

Страница 6: ...000 Btu Hr Manifold Pressure 10 WC 2 50 kPa 10 WC 2 50 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Mode...

Страница 7: ...0 0 mm min B Vent Surfaces 1 26 mm min Ceiling to Opening 42 1067 mm min Floor 0 0 mm min Perpendicular Wall See Figure 6 Front Service Clearances 3 0 9 M BRT 4036TEN B 4336TEN B 4536TEN B 4036TEP B...

Страница 8: ...5 16 above bottom of appliance The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance see Figure 17 Page 12 4 Repack insulation around...

Страница 9: ...rminated into an attic space or into a chimney flue servicing a solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adap...

Страница 10: ...Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2...

Страница 11: ...eady to use 5 Replace front refractory access panel Figure 16 Manual Shutoff Valve Installation Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Figure 15 Installing Battery...

Страница 12: ...aterial Burner Pan Vermiculite Pan Material Grate EMBER AND PAN MATERIAL PLACEMENT 1 Open bag s of vermiculite and fill until it is even across burner pan see Figure 20 2 Smooth pan material just even...

Страница 13: ...26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26 As an option to enhance t...

Страница 14: ...p right of log 1 see Figure 29 Rest lower end of log 6 on top of log 2B see Figure 30 As an option to enhance the look of the hearth you may place volcanic stone provided around front and sides of bur...

Страница 15: ...31 Pull handle to open or push to close APPLIANCE ENCLOSURE Before finishing enclosure around appliance inspect all joints around outer surround Any gaps between nailing flanges and framing should be...

Страница 16: ...s operating Do not attempt to adjust or clean the glass doors until the appliance has fully cooled CAUTION Always operate the appliance with the doors either fully opened or fully closed Operating the...

Страница 17: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE Duringinitialoperationofnewfireplace burn ing logs will give off a paper burning smell Orange flame will als...

Страница 18: ...ing may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circulating air system be kept clean WARNING Turnoffga...

Страница 19: ...is equipped with a manually reset blocked flue safety limit switch Refer to Figure 42 for its location If during appliance operation the flame goes out independently of the burner on off wall switch...

Страница 20: ...sit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Страница 21: ...an any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replace control valve refer to Re placement Parts Page 20 7 Check th...

Страница 22: ...op of Page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Gas Line Hook Up Page 11 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air hole...

Страница 23: ...36TEP B White Herringbone F3200 BRT4536TEN B White Herringbone F3213 BRT4342TEP B White Stacked F3212 BRT4342TEN B White Stacked F3209 BRT4336TEP B White Stacked F3208 BRT4336TEN B White Stacked F3221...

Страница 24: ...E ASSEMBLY 1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 1 31 J7320...

Страница 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Страница 26: ...45 LOG 11 TOP 1 KEY NO CATALOG NO DESCRIPTION QTY J4097 LOG SET 1 J7242 LOG REAR 27 1 2A J4245 LOG 11 TOP 1 2B J4262 LOG FIRE PIT 15 75 RND Y 1 3 J4244 LOG 13 5 Y TOP SPLIT 1 4 J4261 LOG 15 75 FIREPIT...

Страница 27: ...36 Fixed Glass Door Brushed Brass finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 4...

Страница 28: ...rim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1124 PCBE 36 36 Electronic Ignition NG to LP F112...

Страница 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 32: ...eplace uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...

Отзывы: