Figure 31 - Air Kit Handle Location
Air Kit
Handle
Screen
Figure 32 - Sealing Between Appliance and Framing
Side
Framing
Side
Framing
Caulk Here
Pack Insulation
Figure 33 - Installing Optional Glass Door
Spring Clip
Insert Pin Into Spring Clip
Insert Bottom Pivot Pin Into
Pivot Plate and Swing Door
Into Vertical Position
Pivot Plate
Slide Top
Pin Into
Door Track
INSTALLATION
Continued
6. Repeat process for opposite door assembly.
7. To adjust doors, slide them partially open. Using a screwdriver,
loosen hold-down screws in the spring clip
(see Figure 34, Page
16)
and pivot plate.
8. Close both doors until evenly joined at the middle and note gap at
outer edges of face.
9. Reopen one door at a time and retighten upper and lower hold-
down screws.
CAUTION: Air inlet ducts are not to terminate in
attic space.
CAUTION: Use only glass doors certified for use
with this appliance.
COMBUSTION AIR KIT MODEL AK4 (OPTIONAL)
The outside air kit may be installed on the left side of fireplace only.
The vent can be installed through any outside wall a minimum of three
feet below fireplace termination cap. The handle to operate damper
door for outside air inlet will be located inside left “screen pocket” of
firebox
(see Figure 31)
. Pull handle to open or push to close.
APPLIANCE ENCLOSURE
Before finishing enclosure around appliance, inspect all joints around
outer surround. Any gaps between nailing flanges and framing should
be sealed with noncombustible insulation or caulking.
If appliance is mounted on a raised platform, it must be a continuous
surface and not on blocks without a solid surface. This will prevent
entry of cold air by means of conduction through the total bottom of
appliance
(see Figure 32)
.
INSTALLING OPTIONAL GLASS DOOR ACCESSORY
NOTE:
Glass door may be heavy for some individuals. If this is the
case, please request help if needed.
The BRT4036, BRT4336, BRT4536, BRT4042, BRT4342 and BRT4542
B-vent fireplaces are approved for use with optional bi-fold glass
doors
(see Accessories, Page 27).
Glass panels may be ordered and
installed anytime after fireplace installation is complete.
Follow these steps to install left and right panels:
1. With handle at the bottom, completely fold panel on its hinges.
2. With handle facing center of firebox opening, insert lower pivot pin on
glass door panel into hole in pivot plate on bottom edge of fireplace
opening
(see Figure 33).
3. Keeping folded door tilted, slide upper two pins into guide track
found under upper facial edge of firebox opening.
4. Tilt glass assembly fully vertical until outer pivot pin snaps into
mounting hole in upper spring clip
(see Figure 33)
.
5. Once top and bottom pins are secured, unfold door into the closed
position.