background image

SuperiorFireplaces.us.com

900807-00_A

13

Figure 23 - Installing Logs 1 and 2

Figure 24 - Installing Logs 3 and 4

Figure 25 - Installing Logs 5 and 6

INSTALLATION  

Continued

LOG PLACEMENT FOR MODEL BRT 4036TEN-B 4336TEN-B, 

4536TEN-B, 4036TEP-B, 4336TEP-B, 4536TEP-B
1.  Place small front right log (log 1) on right front of grate as shown 

in 

Figure 23

.

2.  Place large back log (log 2) onto grate making sure notches rest 

over grate as shown in 

Figure 23

.

3.  Place log 3 into notch on log 2, resting front end on top of log 1 

(see Figure 24).

4.  Place upper end of log 4 into notch on log 2 as shown in 

Figure 

24

. Rest lower end of log 4 onto middle grate finger as shown in 

Figure 25

.

5.  Place upper end of log 5 into notch on left of log 2 

(see Figure 

25). 

Rest lower end of log 5 on grate as shown in 

Figure 26

.

6.  Insert lower end of log 6 between first two grate fingers as 

shown in

 Figure 26 

and position upper end of log 6 into notched 

area on front of log 2 as shown in 

Figure 26

.

As an option to enhance the look of the hearth, you may place volcanic 

stone provided around front and sides of burner.

NOTE: It is important to ensure proper log placement per the manual 

when installing these units. Verify pilot flame is not obstructed. See 

Inspecting Pilot and Burner Flame Patterns on Page 18.

NOTICE: Do not put volcanic stone inside the burner 

pan or around the air mixer fitting. Placing volcanic 

stone inside the burner pan or blocking the openings 

of the propane/LP air mixer could cause performance 

problems.

1

J4246

LOG, FIREPIT SPLIT 9"

2

J7241

LOG, REAR 22"

3

J4242

LOG, TOP ROUND 11-3/4"

4

J4243

LOG, TOP SPLIT 16"

5

J4244

LOG, Y TOP SPLIT 13-1/2"

6

J4245

LOG, TOP 11"

Log 1

Log 2

Notch

Log 3

Log 4

Notches

1

2

Log 5

Log 6

Notch

Notch

3

4

2

1

Figure 26 - Logs Installed for 36" Models

1

2

3

4

5

6

Содержание BRT4036TEN-B

Страница 1: ...ppelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installatione...

Страница 2: ...d its installation complies with State and Local Codes and in the absence of these codes complies with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Natural Gas and Propane Installation Code C...

Страница 3: ...depth of the fireplace 17 Do not use fireplace if any part has been exposed to or under water Immediately call a qualified service person to arrange for replacement of the unit 18 Do not operate fire...

Страница 4: ...nner other than instructed in this manual D Burning of anything other than the type of gas approved for use in this gas appliance UNPACKING The following items are packed inside the firebox Remove bef...

Страница 5: ...INSTALLATION FLUSH INSTALLATION WARNING Installation of this appliance should be done by a qualified service person well trained in the installation of such appliances You will also need a building pe...

Страница 6: ...000 Btu Hr Manifold Pressure 10 WC 2 50 kPa 10 WC 2 50 kPa Minimum Supply Pressure 11 WC 2 74 kPa 11 WC 2 74 kPa Maximum Supply Pressure 13 WC 3 23 kPa 13 WC 3 23 kPa Orifice Size 52 50 Model 36 Mode...

Страница 7: ...0 0 mm min B Vent Surfaces 1 26 mm min Ceiling to Opening 42 1067 mm min Floor 0 0 mm min Perpendicular Wall See Figure 6 Front Service Clearances 3 0 9 M BRT 4036TEN B 4336TEN B 4536TEN B 4036TEP B...

Страница 8: ...5 16 above bottom of appliance The gas line must be installed through lower left side access point or alternate access hole in the bottom of appliance see Figure 17 Page 12 4 Repack insulation around...

Страница 9: ...rminated into an attic space or into a chimney flue servicing a solid fuel burning appliance This appliance may be vented through a manufactured chimney system or a masonry chimney using a B vent adap...

Страница 10: ...Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2...

Страница 11: ...eady to use 5 Replace front refractory access panel Figure 16 Manual Shutoff Valve Installation Typical Exterior Wall Gas Shutoff Installation Key Extension Shutoff Valve Figure 15 Installing Battery...

Страница 12: ...aterial Burner Pan Vermiculite Pan Material Grate EMBER AND PAN MATERIAL PLACEMENT 1 Open bag s of vermiculite and fill until it is even across burner pan see Figure 20 2 Smooth pan material just even...

Страница 13: ...26 6 Insert lower end of log 6 between first two grate fingers as shown in Figure 26 and position upper end of log 6 into notched area on front of log 2 as shown in Figure 26 As an option to enhance t...

Страница 14: ...p right of log 1 see Figure 29 Rest lower end of log 6 on top of log 2B see Figure 30 As an option to enhance the look of the hearth you may place volcanic stone provided around front and sides of bur...

Страница 15: ...31 Pull handle to open or push to close APPLIANCE ENCLOSURE Before finishing enclosure around appliance inspect all joints around outer surround Any gaps between nailing flanges and framing should be...

Страница 16: ...s operating Do not attempt to adjust or clean the glass doors until the appliance has fully cooled CAUTION Always operate the appliance with the doors either fully opened or fully closed Operating the...

Страница 17: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS NOTICE Duringinitialoperationofnewfireplace burn ing logs will give off a paper burning smell Orange flame will als...

Страница 18: ...ing may be required due to excessive lint from carpeting bedding material pet hair etc It is imperative that the control compartments burners and circulating air system be kept clean WARNING Turnoffga...

Страница 19: ...is equipped with a manually reset blocked flue safety limit switch Refer to Figure 42 for its location If during appliance operation the flame goes out independently of the burner on off wall switch...

Страница 20: ...sit our web site at SuperiorFireplaces us com REPLACEMENT PARTS See Pages 23 to 26 for a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be orde...

Страница 21: ...an any other possible obstructions 4 Contact your gas supplier to check pressure 5 Have a qualified technician replace pilot line 6 Replace control valve refer to Re placement Parts Page 20 7 Check th...

Страница 22: ...op of Page 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all leaks see Gas Line Hook Up Page 11 Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air hole...

Страница 23: ...36TEP B White Herringbone F3200 BRT4536TEN B White Herringbone F3213 BRT4342TEP B White Stacked F3212 BRT4342TEN B White Stacked F3209 BRT4336TEP B White Stacked F3208 BRT4336TEN B White Stacked F3221...

Страница 24: ...E ASSEMBLY 1 J4055 GRATE ASSEMBLY 1 27 J4048 PAN BURNER 1 J4049 PAN BURNER 1 28 J4053 TUBE BURNER 1 J4083 TUBE BURNER 1 29 J4051 BRACKET BURNER 1 30 J4094 SHIELD PILOT 1 J4095 SHIELD PILOT 1 31 J7320...

Страница 25: ...F3224 Refractory Set White Stacked 1 12 Refractory Left 1 13 Refractory Right 1 14 Refractory Rear 1 15 Refractory Bottom 1 16 J6379 Refractory Bottom Front White Herringbone 1 16 J6374 Refractory Bot...

Страница 26: ...45 LOG 11 TOP 1 KEY NO CATALOG NO DESCRIPTION QTY J4097 LOG SET 1 J7242 LOG REAR 27 1 2A J4245 LOG 11 TOP 1 2B J4262 LOG FIRE PIT 15 75 RND Y 1 3 J4244 LOG 13 5 Y TOP SPLIT 1 4 J4261 LOG 15 75 FIREPIT...

Страница 27: ...36 Fixed Glass Door Brushed Brass finish F0998 FD36P 36 Fixed Glass Door Platinum finish F0999 FD42 42 Fixed Glass Door Black finish F1000 FD42B 42 Fixed Glass Door Brushed Brass finish F1001 FD42P 4...

Страница 28: ...rim Kit Black F1046 PT42B 42 Perimeter Trim Kit Brushed Brass F1047 PT42P 42 Perimeter Trim Kit Platinum PROPANE NATURAL GAS CONVERSION KIT Not Shown F1124 PCBE 36 36 Electronic Ignition NG to LP F112...

Страница 29: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 32: ...eplace uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...

Отзывы: