SuperiorFireplaces.us.com
126829-01C
19
CONCRETE LOG MODELS LBG
(18,24,30) BM
NOTE
: Your appliance may vary from model
shown but log placement will be the same.
1. Before placing any logs on the chassis you
will need to remove the Air Shield located
on the left side near the rear burner as
shown in
Figure 25
. The Air Shield is held
in place with one screw, remove the Air
Shield and place the screw back into the
hole in the chassis. Place the Air Shield
with your owner's manual and keep.
2. Place fiber ramp log in center of chassis
as shown in
Figure 26
. The fiber ramp
log can be identified by the shape and
much lighter weight when compared to
the other logs. The log must sit flat on the
black sheet metal and behind the left metal
tab as shown. Make sure the side marked
''BOTTOM'' is setting down.
INSTALLATION
Continued
LBG(18,24,30)SM MODELS
LBG36SM MODELS
Figure 24 - Correct Log Placement
8. For LBG36SM, position left and right
control cover logs as shown in
Figure
24
. These may be placed as desired to
hide controls.
Figure 27 - Installing Left/Right Front Logs
Left Front
Log
Right Front Log
Figure 26 - Installing Fiber Ramp Log
Ramp Log
Metal
Tab
3. Place front left (18" D-064, 24" D-057 & 30"
D-038) and front right (18" D-065, 24" D-058
& 30" D-039) logs as shown in
Figure 27
.
Figure 25 - Removing Air Shield
Air Shield
Screw