7
AVSI-12 Interview Room Systems Setup Guide
SECTION 3: SYSTEM SETUP
SECTION 3
System Setup
The basic Interview Room System system includes an ALI-QVR4108H HD-TVI digital video recorder, an HD-TVI 1080p high definition
camera, a hi-gain microphone and speakers.
3.1 Install the recorder hardware
Installing the recorder hardware includes the ALI-QVR4108H HD-TVI recorder and the 24LGLED monitor. A uninterruptible power
supply (UPS), not provided, is strongly recommended. When installing this equipment, refer to the
ALI-QVR4100H 8/16-Channel
AHD, HD-TVI, Analog and IP Camera Recorder Quick Setup Guide
and documentation provided with the monitor and other
system components for more information.
NOTE
Powering the interview room system through a 1000 VA uninterruptible power supply (UPS) is strongly recommended. A UPS is
not provided.
1.
Place the ALI-QVR4108H unit in a secure location that is within cable distance to the interview room(s) you are monitoring,
and in a location that has restricted access. Using the cables provide:
—
Cable (EXT100) between the recorder and the camera and microphone is 100 feet. (Longer cables are available. The
ALI-TS1012R camera can be extended with a cable length up to 1600 feet.
—
Cable (CAB-ASK) between the recorder and the switch is 100 feet.
2.
Become familiar with the back panel of the ALI-QVR4108H recorder. The connection points for the devices included in this
interview room system are shown in the images below.
12 VDC Plug for
power adapter
VIDEO IN CH 1
for camera
AUDIO OUT
to speakers
AUDIO IN CH 1 input
from microphone
LAN
Ground
terminal
Power
switch
HDMI/VGA
to monitor
Alarm Terminations
(See image below)
ALARM IN 1 GROUND (G)