![Sunways NT 2600 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/sunways/nt-2600/nt-2600_user-manual_1401174062.webp)
Fault display
Fault 16
Control error
Causes
The cable cross-section in
the AC feed line to the solar
inverter is too small.
Your PV system feeds
into a stub line which is too
weakly dimensioned.
The intrinsic monitoring
of the solar inverter has
detected an error in the
control.
Remedies
Ask your electricity board about grid
stability and design.
Check the format of your grid connection
(energy counter) and the grid feed-in
point to your electricity board.
Please contact the technical hotline.
You will find the telephone number
on the back of the manual.