![Sunways NT 2600 Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/sunways/nt-2600/nt-2600_user-manual_1401174031.webp)
EN
117
Configuration of the cable terminal block:
Temperature sensor
measuring signal:
Temp
Solar radiation
measuring signal:
Solar
Positive supply, 5V:
V +
Supply, GND:
V –
Using a small screwdriver, press the orange
terminal. The terminal will open.
Insert the cable stripped to a minimum of
11 mm into the respective terminal hole.
Loosen the screwdriver. The cable is fixed
in the connection.
Once again, check that the cable connec-
tion is firmly located.
Содержание NT 2600
Страница 2: ...SOLAR INVERTERS User Manual for Sunways Solar Inverters NT 6000 NT 5000 NT 4000 and NT 2600...
Страница 6: ...1 0 General information 92...
Страница 13: ...200 2 0 Information on installation 99...
Страница 38: ...3 0 Information on operation 124...
Страница 66: ...4 0 Appendix 152...
Страница 85: ...200...