(Fig.) Connection of the alarm relay
Important information: The alarm relay is
designed for 230 V / 2 A. Higher outputs /
voltages can result in destruction of the
relay. The connected signal input must
have separate fuse protection!
Using a small screwdriver, press the orange
terminal. The terminal will open. Insert the
minimum 11 mm stripped cable into the
respective terminal hole. Loosen the screw-
driver. The cable is fixed in the connection.
Once again, check that the cable connec-
tion is firmly located.
EN
The terminals are designed for a cable
cross-section of 0.2 mm
2
to 1.5 mm
2
.
Please also take account of the power
consumption of the connected signal
input when dimensioning the cross-sec-
tion!
!