User Manual for 

Sunways Solar Inverters NT 6000, NT 5000,

NT 4000 and NT 2600

New Version

850 V

Содержание NT 2600

Страница 1: ...200 MANUAL User Manual for Sunways Solar Inverters NT 6000 NT 5000 NT 4000 and NT 2600 New Version 850 V...

Страница 2: ...SOLAR INVERTERS User Manual for Sunways Solar Inverters NT 6000 NT 5000 NT 4000 and NT 2600...

Страница 3: ...95 96 97 98 100 101 102 103 105 106 107 89 General safety information Opening the unit Scope of supply Inspecting the delivery Integration into the PV system Design of the PV generator Standard compo...

Страница 4: ...7 139 143 90 PV generator connection Important Information Communication connections Connection of the alarm relay Connecting the sensors Switching the solar inverter on and off Configurations Display...

Страница 5: ...150 153 155 158 160 164 166 170 91 Warranty terms and conditions Designation and description Functional principle and explanations Block diagram of the Solar Inverter in the PV system Technical data...

Страница 6: ...1 0 General information 92...

Страница 7: ...ical or electrical components are defective Before commissioning the system we strongly advise you to carefully read and heed the instructions Non compliance can have serious consequences for exam ple...

Страница 8: ...es to conduct a hazardous voltage internally and at the connection sockets for ca five minutes after disconnec ting from the PV generator The energy storage capacitors are only fully discharged after...

Страница 9: ...hough our products are carefully packed in recyclable packing transportation damages can still occur These are generally the transport compa ny s responsibility Please inspect the delivered solar inve...

Страница 10: ...ur system Pay attention to the skyward alignment of the modules You will obtain maxi mum yield in Central Europe with a module inclination of 30 to the hori zontal and a direct southerly alignment of...

Страница 11: ...V PV 1 2 4 GRID PV generator switch Designed as DC load break cut out to cut off the PV generator from the solar inverter Dimensioning min 900 V 16 A Grid connection 3 phase Feed in 1 phase grid monit...

Страница 12: ...id voltage 10 minute average value 10 UNOM Fault 15 98 In the event of a fault the conversion is blocked immediately and the grid relay is isolated An alarm relay with floating output is activated not...

Страница 13: ...200 2 0 Information on installation 99...

Страница 14: ...nutes after isolation from the PV generator and the grid The energy storage capacitors are only fully discharged after this period After disconnecting the solar inverter from the grid and PV generator...

Страница 15: ...em from the power grid by opening the grid breaker main fuse and open the DC switch on the PV generator in order to exclude the danger of electric shocks Use a soft dry cloth to clean the system Never...

Страница 16: ...the fixed voltage level The optimal fixed voltage level is dependent on your PV generator model The fixed voltage can be set with the S100 slide switch on the control board At the factory the switch i...

Страница 17: ...nways Solar Inverters in different countries You can make the relevant setting with DIP switch S300 beneath the display panel Country Germany Spain modification Disconnect interval after power failure...

Страница 18: ...alled by a trained qualified electrician A special tool is necessary for installation Please read this chapter very carefully 150 mm Cool air Warm air 300 mm 300 mm 150 mm Fig Minimum distances that m...

Страница 19: ...gularly freed from dust deposits Requirements on the place of installation Mechanical bearing capacity During installation please bear in mind that the solar inverter weighs 26 kg The installation bas...

Страница 20: ...can be led through The unit may only be ope ned by a qualified electrician The cabinet cover must first be released and removed The SUB D connector for the RS 232 con nection is located on the bottom...

Страница 21: ...5000 and NT 4000 and a 3 x 16 A safety cutout for device NT 2600 as grid protection element in the grid feed in direction No consumption units must be connected to the feed line from the solar inverte...

Страница 22: ...inal during feed in If the terminal voltage exceeds the per missible value the solar inverter is dis con nected from the grid In the case of poorly designed electric grids and high PV output this can...

Страница 23: ...at the inverter is appro ved for the maximum PV generator vol tage To achieve the necessary protection against hazardous contact voltage during the installation of PV systems the positi ve and negativ...

Страница 24: ...y The Tyco Solarlok con nectors are designed for a cable cross section of 4 mm2 and must be crimped see chapter 4 2 Tyco Solarlok connec tion Connect the two right DC female connec tors with the two l...

Страница 25: ...he terminals Note chapter 2 1 Safety information The DC voltage can be up to 850 V The unit may only be opened by a qualified electrician Always disconnect the PV generator side first by opening the P...

Страница 26: ...on interfaces are available RS 232 and RS 485 The standard communication interface is the RS 232 interface which is installed in all current PCs and notebooks This inter face allows you to establish c...

Страница 27: ...ewdriver Press the orange terminal The terminal will open Insert the cable stripped to a minimum of 11 mm into the respective terminal hole Release the screwdriver The cable is fixed in the connection...

Страница 28: ...eral solar inverters the individual relays can be parallel connected and connected via a joint signal light Connection Remove the housing of the solar inverter before connecting the status signal rela...

Страница 29: ...er press the orange terminal The terminal will open Insert the minimum 11 mm stripped cable into the respective terminal hole Loosen the screw driver The cable is fixed in the connection Once again ch...

Страница 30: ...ator such as e g shading or failure of solar cells can be detected For demonstration purposes the irradia tion sensor and the corresponding data can be used to show how a PV system functions In conjun...

Страница 31: ...l Solar Positive supply 5V V Supply GND V Using a small screwdriver press the orange terminal The terminal will open Insert the cable stripped to a minimum of 11 mm into the respective terminal hole L...

Страница 32: ...not configured Switching the solar inverter on and off Switching on When the solar inverter is mechanically installed and connected to the electrical cables the unit can be commissioned as follows Swi...

Страница 33: ...ected e g removal from the PV system reconfigured or extended the cabinet cover must be removed Note chapter 2 1 Safety information Open the main switch for the PV DC voltage and the mains fuse as des...

Страница 34: ...ollow the instructions below Direct configuration of the solar inverter occurs in operation Please note that the unit is under DC voltage for configurations via the keys Danger to life Please observe...

Страница 35: ...net cover to carry out the configuration The following settings can be performed using the illustrated keys Address of the solar inverter address 1 is stored in the memory at the factory In the case o...

Страница 36: ...rial to press the keys e g a plastic rod Avoid direct contact with the printed circuit board so that the electronics cannot be damaged by electro static charging Starting from the current display on t...

Страница 37: ...LANGUAGE SOFTWARE VERSION ENGLISH GERMAN ITALIAN FRENCH SPANISH A B LCD CONTRAST CONTRAST A B TOTAL POWER OFFSET kWh A B INCREMENT 100 OR 1 D D D D D D C A B A B A B 123...

Страница 38: ...3 0 Information on operation 124...

Страница 39: ...power of the solar inverter The bottom line 2 outputs operating data The data can be displayed in the German English French Spanish or Italian language if the optional irradiation sensor with integra...

Страница 40: ...verwritten 15 minute values for AC current DC and AC voltages irradiation and temperature 500 times storage of 15 minute average values in the recirculating storage stora ge depth ten days on average...

Страница 41: ...he RS 232 and RS 485 interfaces as stan dard In the case of larger distances bet ween PV system and PC the data can also be transferred via a modem We recom mend using two external analogue modems mad...

Страница 42: ...software Connect the powered remote modem to the PC via the COM port Use the inter face cable provided with the modem for this purpose Start the Sunways NT Monitor and set Acer Modem under the Setting...

Страница 43: ...rface on the bottom of the device Jumper JP400 open Connection and circuitry options 1 An individual solar inverter can be read out using this connection unless the distance from the PC exceeds a dist...

Страница 44: ...r Jumper JP400 open 2 For installation of the remote inquiry of an individual solar inverter the RS 232 signal can be conducted directly from the solar inverter to the remote modem via the SUB D conne...

Страница 45: ...solar inverter that is furthest away from the interface converter It must be open for all other solar inverters Stripped length 11 mm Jumper JP400 see above 3 Up to 99 solar inverters can be connec t...

Страница 46: ...inverter at the other termi nal The RS 485 signal is led out of the last solar inverter in the series into the interface converter using the following configuration RS 485 to DATA and RS 485 to DATA T...

Страница 47: ...o the remote inquiry then the individual inverters are connected together by means of the RS 485 signal as when reading out several units locally This signal is converted by the interface converter in...

Страница 48: ...to PC 9 pole 1 2 3 4 5 6 7 8 9 5 4 3 2 1 9 8 7 6 Cable type 2 Provided in the scope of supply of the Acer modem Connector to modem 9 pole 1 2 3 4 5 6 7 8 9 5 4 3 2 1 9 8 7 6 9 pole female connector t...

Страница 49: ...0 depending on your selected communication circuit This jumper is located above the RS 485 communication connection in the lower section of the board 1 2 3 4 5 6 7 8 9 Cable type 3 Connector to modem...

Страница 50: ...ate and daily energy in the solar inverter Representation as graphic or print Option of saving as bitmap Zoom in of graphics possible Individual solar inverters can be called up with the scroll menu M...

Страница 51: ...ake change key If you are using several solar inverters and wish to make a change to the numbering you can enter the old number of the solar inverter in the top section of the right window half and th...

Страница 52: ...ues in the same way by clicking on the respective keys Exit the window with the Close key You will return to the Settings menu Help menu You will find further helpful information on operating the Sunw...

Страница 53: ...y monitors the grid frequency If this is outside the range permitted by DIN V VDE V 0126 1 1 the solar inverter will stop the feed and Fault 4 will be indicated EN Fault 5 Overheating Your solar inver...

Страница 54: ...Fault 11 DC feed Your solar inverter constantly monitors the quality of the fed in current The solar inverter stops the feed as soon as an Fault 7 Grid overvoltage 1 phase Your solar inverter constant...

Страница 55: ...monitored If the level exceeds the maxi mum permissible limit value the solar inverter stops the feed and only restarts it when the voltage value falls below the maximum permissible limit value Fault...

Страница 56: ...ibe the current status of the solar inverter LED green LED red LED green LED red LED green LED red illuminated off flashing flashing off illuminated Solar inverter operating in normal mode Solar inver...

Страница 57: ...as been exceeded The necessary air circulation was not taken into account during installation Objects have been stored on the heat sink impeding free convection Remedies Check the dimensioning of your...

Страница 58: ...within the limits The fault cut out can be triggered even if the values only exceed or fall below the limits very briefly Ask your electricity board about grid stability and design Check the format o...

Страница 59: ...the format of your grid connection energy counter and the grid feed in point to your electricity board The solar inverter monitors the limits of the minimum and maximum permissible 3 phase grid volta...

Страница 60: ...detected a DC component 1 A in the grid current Dropout of monitored phase L2 or L3 Phase difference between individual grid conductors outside the permitted limit values Remedies Check the format of...

Страница 61: ...es off and only restarts automatically when the voltage value has returned within the limits The fault cut out can be triggered even if the values only exceed or fall below the limits very briefly Ask...

Страница 62: ...ly dimensioned The intrinsic monitoring of the solar inverter has detected an error in the control Remedies Ask your electricity board about grid stability and design Check the format of your grid con...

Страница 63: ...ered with snow Remedies Have the battery button cell replaced by an expert The battery is located on the LCD display board This can occur with high ambient tempe ratures The display will operate norma...

Страница 64: ...ance within seven days of purchase Please notify us of any warranty claims by telephone stating your name address telephone and serial number and your email address if applicable You will find the tel...

Страница 65: ...mage vandalism fire overvoltage thunderstorms etc Inappropriate transport Non observance of pertinent regulations or incorrect installation or commissioning Leakage of overvoltages from the varis tors...

Страница 66: ...4 0 Appendix 152...

Страница 67: ...Universal Sensitive Residual Current RCD Residual Current Device Direct Current PV generator side of the solar inverter Electromagnetic Compatibility Electricity Board Current used to operate the sol...

Страница 68: ...of grid impedance DC and AC rated power Power which the inverters can permanently consume DC or emit AC Temperature sensor Photovoltaic DC load break switch to cut off the PV generator from the solar...

Страница 69: ...during conversion The concept of the Sunways Solar Inverter is completed by a rapid MPP control which maintains the MPP point with a very high adaptation efficiency DC and AC filters The DC and AC fil...

Страница 70: ...t the solar inverter to the grid The AFI of the Sunways solar inverter complies with standard DIN V VDE V 0126 1 1 In addition the AFI of Solar Inverters NT 6000 NT 5000 NT 4000 and NT 2600 has an abs...

Страница 71: ...The solar inverter has a rapid MPP control which maintains the MPP point with a very high adaptation efficiency If surplus power is provided by the PV generator the solar inverter limits this by shift...

Страница 72: ...gram of the solar inverter in the PV system HERIC DIFFERER MEASUREMENT RT IRRADIATION SENSOR AND TEMPERATURE SENSOR OPT RS 232 RS 485 MICRO CONTROLLER CONTROL DATAPRO TEMP CONTROLLER IDC UDC RADIATION...

Страница 73: ...CURRENT IMPRESSION INDUCTOR AC FILTER GRID PROTECTION RESIDUAL CURRENT AFI DIFFERER MEASUREMENT LCD DISPLAY 2 LINES KEYBOARD AND CESSING AFI UAC IAC GRID L1 N L2 L3 PE 159...

Страница 74: ...rent Number of inputs Maximum efficiency European efficiency weighted HERIC topology Rated continuous output power Pn Maximum power Pp Nominal frequency Grid voltage Nominal current Maximum current Di...

Страница 75: ...sinusoidal 4000 to 6250 W 5200 W 9 W 0 15 W 15 W 400 V 350 UMPP 750 V 850 V 410 V 340 V 18 A 13 A 2 with adapter 4 97 per cent 96 3 per cent yes 4600 W 5000 W 50 Hz 230 V 20 A 21 7 A 3 per cent 1 sinu...

Страница 76: ...y System of protection against envir influences Relative air humidity max Cooling Ambient temperature Celsius Dimensions height x width x depth Weight Noise development Standard warranty period option...

Страница 77: ...ve integrated current source 25 A 3 1 external RS 232 RS 485 status signal relay irradiation temperature LCD 2 x 16 characters IP 54 95 per cent free convection 25 C to 40 C 515 x 300 x 190 mm 26 kg s...

Страница 78: ...upted at a sui table point The cables must be provided with a suitable adhesive label close to the Tyco Solarlok connector The Tyco Solarlok connectors must always be disconnected from other vol tage...

Страница 79: ...closed Tyco Solarlok connectors are equipped with circular contacts for a cable cross section of 4 mm The enclosed seals have internal dimensions of 6 for cables of 5 3 to 6 2 mm sheath diameter and 8...

Страница 80: ...uipment for use in power instal lations 1998 Explanation This product is a component intended for further assembly Due to the features resulting therefrom the product cannot initially meet requirement...

Страница 81: ...3 3 E DIN VDE 0126 1 1 Explanation Maintaining the EMC guideline assumes an EMC adapted installation of the component within the plant or the machine Please pay attention to the installation notes of...

Страница 82: ...10Min Smax10Min SN Solar Inverter Sunways AG Photovoltaic Technology Macairestr 3 5 D 78467 Konstanz Explanation The maximum output power of the solar inverter has to be declarated as a max 10 minute...

Страница 83: ...5 D 78467 Konstanz Sunways NT 6000 NT 5000 NT 4000 NT 2600 2005 05 02 In plant generation on low voltage guidelines 4 Edition 2001 Explanation The NT series of solar inverters from Sunways are monoph...

Страница 84: ...means without prior written permission of Sunways AG Sunways AG does not provide any war ranty for damages due to defective or lost data incorrect operation or mal functioning of the solar inverter t...

Страница 85: ...200...