Function code: 03H Modbus response (measurement parameter)
Logic
address
(Hex)
R/W Item
Number
of
Byte
Information
type
Description of data
transmission
Default value
Note
0031 R
Number of
measurement
channels
2 USHORT
0: Hold Status
1
1: Measurement
0032
R Parameter
unit
6 CHAR
mg/l
mg/l
ASCII
code
0035 R
Free Cl
2
measurement
4 FLOAT
Free Cl
2
measurement
Data
affected
by
parameter
unit
0037 R
Temperature
measurement
4 FLOAT
Temperature
measurement
0039 R
pH
measurement
4 FLOAT
pH
measurement
0041-
0050
Factory reserved
Function code: 01H Modbus response (dispersion parameter)
Logic
address
(Hex)
R/W
Item BIT
Description
Default
value
Note
0070
R
LO Alarm
1
Contact on
0 (Contact off)
0071
R
HI Alarm
1
Contact on
0 (Contact off)
0072
R
mA too high
1
Contact on
0 (Contact off)
0073
R
mA too low
1
Contact on
0 (Contact off)
0074
R
Exceed temp. range
1
Contact on
0 (Contact off)
0075
R
Exceed
pH range
1
Contact on
0 (Contact off)
0076
R
RLY1 Action
1
Contact on
0 (Contact off)
0077
R
RLY2 Action
1
Contact on
0 (Contact off)
0078
R
Cln/Auto Zero Action
1
Contact on
0 (Contact off)
0079 R Measurement
status 1
Contact on
1 (Contact on)
0: Hold
1: Measurement
007A
R
Exceed Free Cl
2
range
1
Contact on
0 (Contact off)
007B
R Free
Cl
2
electrode open
1
Contact on
0 (Contact off)
007C R
Motor
action
1
Contact on
1 (Contact on)
007D-
0090
Factory reserved