91
13.13) ADJUSTING X, Y SCOPE LIMITS
1) Adjusting X scope limit
Manually move the frame to a point, where
the right end of the frame clip is 45.5mm
from the center of the needle hole on the #1
bed (see figure)
②
Adjust the origin detecting sensor on the left
of the X-axis LM guide as shown in figure
and fasten the sensor base.
After adjusting the origin point on the X axis, turn on the main switch and press the X frame
movement key on the operation box. When the frame reaches the limit of the X scope (interval
between heads: ex. 330. 300. 275. 400 mm. See FRAME-X on the screen), turn off the machine. Fix
the position of the limit sensor on the right of the LM guide as shown in figure.
Center of the
needle hole on
#1 bed
18.5mm
45.5mm
Screw on the
origin detecting
sensor base
Sensor plate
Origin detecting sensor
Sensor board
Limit base screw
limit sensor
X frame movement key