Serial Flash Programmer[S550-SFWv3] Operation Manual
115
9.5.
List of Error Information on Center Display
Center display status
Descriptions
"0","0"
Programming is canceled after S550-SFWv3 main unit started up.
"0","1"
Programming completed successfully.
"0","2"
Occurs when failed in mode entry before programming.
"0","3"
Occurs when failed in checking IDs.
"0","4"
Occurs when failed in erasing.
"0","5"
Occurs when failed in programming.
"0","6"
Occurs when failed in verifying.
"0","7"
Occurs when failed in Blank.
"0","8"
Occurs when failed in Protect.
9.6.
Execution Detail Screen List
Error
Descriptions
Pass
Programming completed successfully.
Mode Entry Err
Occurs when failed in mode entry before programming.
・
Error factor in ”Factor”
ID Err
Occurs when failed in checking IDs.
・
Error factor in “Factor”
Erase Err
Occurs when failed in erasing.
・
Error factor in “Factor”
・
Erase method in “Erase Type”
・
Erase block number in “Block No”
Program Err
Occurs when failed in programming.
・
Error factor in “Factor”
・
Program execution address in “Address”
Blank Err
Occurs when failed in Blank.
・
Error factor in “Factor”
Verify Err
Occurs when failed in verifying.
・
Error factor in “Factor”
・
Verify execution address in “Address”
・
Expectation data in “Write Data”
・
Actual data (read value) in “Read Data”
Protect Err
Occurs when failed in protect.
・
Error factor in “Factor”