Serial Flash Programmer[S550-SFWv3] Operation Manual
107
8.3.4.
Programming Information Display
The S550-SFWv3 displays the programming information of the data stored in the internal memory of the main
unit on the center display. Following shows how to see the information.
*When there is no data downloaded to the internal memory, the display does not change to “
Programming Information Display Mode
”.
Also, when the S550-SFWv3 main unit is in energy saving mode, the display does not change to “
Programming Information Display
Mode
”
.
①
Move to “
Programming Information Display Mode”
・
When center display is in the “
Checksum Display Mode
”, press the “FUNC” switch on S550-SFWv3 once,
and ”
D.
”,”
D.
” appear on the center display.
②
Show programming information
・
After ”
D.
”,”
D.
” are displayed on the center display, press the “START” switch on S550-SFWv3 once, and the
MCU, TYPE, and Action Mode are displayed.
*”When there is no operation for 3 seconds after “
D.
”,”
D.
” are displayed, the center display goes back to the “
Normal Display Mode
”.
・
The checksum is automatically scrolled.
③
Exit “
Programming Information Display Mode
”
・
Press the “FUNC” switch on S550-SFWv3 once to go back to the “
Normal Display Mode
”.
(Multi Data Mode)
“Programming Information Display Mode”
shows ”1.”,”
D.
” through ”
4.
”,”
D.
” on the center display.
8.3.5.
Error Information Display
The S550-SFWv3 displays the previous programming error information on the center display. Following shows
how to see the information.
*When there is no data downloaded to the internal memory, the display does not change to “
Error Information Display Mode
”. Also, when
the S550-SFWv3 main unit is in energy saving mode, the display does not change to “
Error Information Display Mode
”.
①
Move to “
Error Information Display Mode
”
・
When center display is in the “
Programming Information Display Mode
”, press the “FUNC” switch on
S550-SFWv3 once, and ”
D.
”,”
E.
” appear on the center display.
②
Shows error information
・
Within 3 seconds after ”
D.
”,”
E.
” are displayed on the center display, press the “START” switch on
S550-SFWv3 once, and the error information is displayed.
*When there is no operation for 3 seconds after “
D.
”,”
E.
” are displayed, the center display goes back to the default screen.
*For details of error information, check the error information details (See “9.4 List of Error Information on Center Display”)
③
Exit “
Error Information Display Mode
”
・
Press the “FUNC” switch on S550-SFWv3 once to go back to the default screen.
(Multi Data Mode)
“Error Information Display Mode”
shows ”
1.
”,”
E.
” through ”
4.
”,”
E.
” on the center display.