6 Appendices
Quick User Manual
46
Weight 20
kg
Backup Data
Nominal voltage
230 Vac (±2 %)
Total harmonic factor output
4 % (full load)
Frequency range
50 Hz (±0.2 %)
Switch time to emergency mode
10 s
Power factor
0.8 overexcited/leading–0.8
underexcited/lagging
Max. output power
5000 W / 5000 VA
Max. output power (battery mode)
3000 W / 5000 VA
6.2
STB5K (backup box) Technical Data
Max. input / output current
25 A
Nominal AC voltage
230 Vac–240 Vac
AC voltage range
180 Vac–275 Vac
Operating ambient temperature range
-25
℃
to 60
℃
*
Power consumption
< 3 VA / 2 W
Dimensions (W x H x D)
220 mm x 230 mm x 90 mm
Mounting method
Wall-mounting bracket
Weight 2.6
kg
* The AC voltage ranges from 180 Vac to 250 Vac when the operating ambient
temperature is 50
℃
–60
℃
.
Meter Technical Data
Nominal voltage
240 Vac
Input voltage range
180 Vac–286 Vac
Power consumption
< 2 W (10 VA)
Max. operating current
100 A
Grid frequency
50 Hz
Measurement accuracy
Class I
Interface and communication
RS485
Ingress protection rating
IP20
Operating temperature range
-25
℃
to 75
℃
Allowable relative humidity range
0–95 %
Dimensions (W x H x D)
18 mm x 117 mm x 65 mm
Mounting method
35 mm DIN-rail
Weight 0.2
kg
Содержание SH5K
Страница 1: ...SH5K QUEN Ver14 201708 Version 1 4 Quick User Manual SH5K Grid Connected Hybrid Inverter ...
Страница 2: ......
Страница 4: ...II System Overview ...
Страница 5: ...III ...
Страница 6: ...IV ...
Страница 7: ...V ...
Страница 8: ...VI ...
Страница 9: ...VII ...
Страница 10: ...VIII ...
Страница 32: ...3 Commissioning Quick User Manual 20 Fig 3 2 Initial Settings ...