5 Operation
Quick User Manual
34
Tab. 5-2
Protective Parameter Explanations
Parameter
Explanation
Vmax-recover
Recovery value for over-voltage fault. Inverter can start
operating only when the grid voltage is below this value.
Vmin-recover
Recovery value for under-voltage fault. Inverter can start
operating only when the grid voltage is above this value.
Fmax-recover
Recovery value for over-frequency fault. Inverter can start
operating only when the grid frequency is below this value.
Fmin-recover
Recovery value for under-frequency fault. Inverter can start
operating only when the grid frequency is above this value.
Power Ramp Rate
The ramp rate of power variation.
10-min Over Vtg
Over-voltage protection value of 10-min average voltage
Reconnect Time
For Italy only.
5.6
Setting the Communication Parameters
Main Screen (Press ENT)
→
Menu (Press
×
2)
→
Settings (Press ENT)
→
Input
password 111 (Press ENT)
→
Settings (Press ×7)
→
Comm. Param (Press
ENT)
Ethernet:
−
The communication address ranges from 1 to 247.
−
The IP, sub net, gateway, DNS1 and DNS2 can be
modified only when the DHCP is set to OFF.
−
Acquire the IP, subnet mask, gateway, DNS1 and
DNS2 from the network professional.
WiFi:
Press
ENT
to enable this function and then you can
connect the inverter WiFi to your home router quickly
with SolarInfo Moni APP. For details, see the manual
delivered with the WiFi module.
Содержание SH3K6
Страница 1: ...SH3 6_4 6K QUEN Ver12 201710 Version 1 2 Quick User Manual SH3K6 SH4K6 Grid Connected Hybrid Inverter ...
Страница 2: ......
Страница 4: ...II System Overview ...
Страница 5: ...III ...
Страница 6: ...IV ...
Страница 7: ...V ...
Страница 8: ...VI ...
Страница 28: ...3 Commissioning Quick User Manual 18 Fig 3 2 Initial Settings ...