Installing the Server Into a Rack
53
FIGURE:
Inserting the CMA Slide-Rail Connector Into the Back of the Left Slide-Rail
7. To verify that the slide rails and the CMA are operating properly before routing
cables through the CMA, perform the following steps.
a. To prevent the rack from tipping forward when the server is extended, extend
all rack anti-tilt devices.
Caution –
To reduce the risk of personal injury, stabilize the rack cabinet and extend
all anti-tilt devices before extending the server from the rack.
For instructions for stabilizing the rack, see
“Stabilize the Rack for Installation”
on page 25
.
b. Slowly pull the server out of the rack until the slide-rails reach their stops.
Figure Legend
1
CMA slide-rail connector
2
Left slide-rail