Chapter 11
Cabling the Switch
97
▼
To Install Cable Trays
1. Lift the cable tray into a horizontal orientation, with the rolled edge towards
you and the lip on the underside.
2. Locate where you want the cable tray to install.
3. Move the cable tray between and just above the branches of the cable tree for
the slot where you want to install the tray.
Slide the far end of the tray into the guides.
4. Continue to press the tray into the guides until the tray stops, then lower the
front of the tray onto the flanges.
See
.
FIGURE 11-3
Installing Cable Trays
Note –
Install cable trays only as they are needed. If all cable trays are installed
before the switch is cabled, the trays’ presence makes cabling extremely difficult.