Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
Prepare the server module for service. See
“How to Prepare the Server Module for Service”on
page 25
.
Remove the service processor (SP) board. See
“How to Remove the Service Processor Board”on
page 53
.
To dislodge the battery from its holder, gently push the top edge of the battery away from the
battery holder.
See frame [1] in
“Battery Replacement Illustration” on page 37
.
Remove the battery.
See frame [2] in
“Battery Replacement Illustration” on page 37
.
Orient the new battery so that the '+' symbol faces away from the battery holder.
To install the battery, insert it into the holder and press it into position.
See frames [3] and [4] in
“Battery Replacement Illustration” on page 37
.
Install the SP board. See
“How to Install the Service Processor Board”on page 54
.
Clear the CMOS NVRAM. See
“Clearing CMOS NVRAM and Resetting Passwords”on page 79
.
The BIOS settings revert to the default settings.
See
“Clearing CMOS NVRAM and Resetting Passwords” on page 79
.
To customize the BIOS settings, access the BIOS Setup Utility and make the necessary changes.
See
“How to Configure the BIOS Using the BIOS Setup Utility”on page 95
.
Prepare the server module for operation. See
“Preparing the Server for Operation”on page 34
.
Removing and Installing DIMMs
This section describes how to diagnose and replace faulty DDR3 LV DIMMs.
Note –
This component is a customer-replaceable unit (CRU).
Use these topics procedures to remove and install DIMMs:
1
2
3
4
5
6
7
8
9
10
Removing and Installing DIMMs
39