How to Remove DIMMs
Note –
This component is a customer-replaceable unit (CRU).
Note –
The Sun Blade X6275 M2 Server module is a dual-node server. If necessary, use this
procedure for
both
nodes.
See
“How to Identify Faulty DIMMs” on page 40
.
Prepare the server module for service. See
“Preparing the Server for Service”on page 25
.
Rotate both DIMM slot ejectors outward as far as they will go.
This action partially ejects the DIMM from the slot.
Carefully lift the DIMM straight up to remove it from the slot.
Prepare the server module for operation. See
“How to Prepare the Server Module for Operation”
on page 34
.
“How to Install DIMMs” on page 45
Before You Begin
1
2
3
4
See Also
DIMM Population Rules and Guidelines for the Sun Blade X6275 M2 Server module
Sun Blade X6275 M2 Server Module Service Manual • March, 2013
44