15
16
Sr.
No.
Parameter setting method
Description of parameters and functions.
Parameter
Sr.
No.
Parameter setting method
Description of parameters and functions.
Parameter
KEYPAD LOCK
33
parameter, press the SET key.
To change Keypad Lock
NO
YES
NO
Function: To activate Keypad Lock.
This parameter can lock the keypad so
that tempering is not possible by by-
standers.
YES - activates keypad lock.
When locked all parameters can only be
viewed, but not modified.
NO - deactivates keypad lock.
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set
NO
YES
NO
To change CCRH parameter,
press the SET key.
CCRH
32
Function : Clear Compressor Run Hours.
If this parameter is set to ‘YES’
compressor run hours (CRH) are
cleared.
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set
Example :
If this parameter is set to 7
mins then, when light is switched on after
7 mins it will be switch off automatically.
To change CRH parameter,
press the SET key.
CRH
Parameter
31
Function: Compressor run Hours.
It will display compressor run hours. It's
a read only parameter.
0
9999
0
To change PW parameter,
press the SET key.
PW
Parameter
29
Function : To change password.
Use UP/DOWN key to change password.
User can enter into program
mode only if correct password is
entered. If the password is wrong it will
show ‘INVALID PASSWORD’.
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set
NO
YES
NO
To change FS parameter,
press the SET key.
FS
Parameter
Function : To restore default settings of
the controller.
When set to YES all parameters
are programmed to factory
values.
Useful to debug setting related
problems.
Use UP/DOWN keys to set desired value.
23
30
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set
LD
Parameter
Use UP/DOWN keys to set desired
value.
This parameter is used set the time
delay to automatically switch off the light.
If LD is set to 0 then this parameter is
disabled.
28
Function : To set time delay to switch off
the light .
To change LD parameter,
press the SET key.
0 Min
30 Min
7 Min
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set
DIS
ENB
DIS
press the SET key.
To change PO parameter,
PO
Parameter
Function : To enable/disable Power
Switch.
Use UP/DOWN keys to get desired
value & press SET key to confirm.
DIS = Disable power switch.
ENB= Enables power switch.
Controller has power switch, which
if enable puts controller in active or
stand by state.
If press for 2 seconds controller will
go in stand by mode, display will
scroll message “STAND BY MODE”.
To again switch to ACTIVE WORKING
MODE, press power switch again for 2
seconds.
23
34
Range
Min
Max
Fact. Set
Range
Min
Max
Fact. Set