Thermistor Location Code Tables
700TC/I-2
THERMISTOR LOCATION
CODE
Freezer Compartment
F
Refrigerator Compartment
r
Freezer Evaporator
FE
Refrigerator Evaporator
rE
700TR-2
THERMISTOR LOCATION
CODE
Lower Compartment
L
Upper Compartment
U
Lower Evaporator
LE
Upper Evaporator
UE
700TF/I-2
THERMISTOR LOCATION
CODE
Freezer Compartment
F
Freezer Evaporator
FE
700BR-2
THERMISTOR LOCATION
CODE
Lower Compartment
L
Upper Compartment
U
Evaporator
E
700BF/I-2
THERMISTOR LOCATION
CODE
Freezer Compartment
F
Evaporator
E
700TF/I-2V
THERMISTOR LOCATION
CODE
Compressor Speed
SP
Freezer Compartment
F
Freezer Evaporator
FE
For Base Unit Temperature Problems - Regardless of Serial Number
1.
Begin troubleshooting by observing compartment set points.
2.
If set-points are normal, initiate Diagnostic Mode by pressing and holding either COLDER key, then press UNIT
ON/OFF key, then release both keys.
NOTE:
Diagnostic Mode will end twenty seconds after the last key stroke.
3.
Toggle to and observe appropriate evaporator temperature.
(See Thermistor Location Code Tables on following
NOTE:
Verify compressor is operating before observing evaporator temperature. If problem is in a refrigerator
section, refrigerator door must be left open for 5 minutes with compressor running.
4.
After observing evaporator temperature as instructed above, take note of
“Pointers”
in first column of trou-
bleshooting guide under problems “AA” and “BB”. The
“Pointers”
list what possible causes to check based on
evaporator temperature observed.