EVAPORATOR TEMPERATURE / SEALED SYSTEM LOW-SIDE PRESSURE CORRELATION
Pressure
10” Vac
7” Vac
4” Vac
0” Vac
2 Psi
4 Psi
7 Psi
9 Psi
12 Psi
15 Psi
18 Psi
22 Psi
26 Psi
30 Psi
35 Psi
40 Psi
45 Psi
51 Psi
57 Psi
64 Psi
71 Psi
78 Psi
Temp °F
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
NOTE:
The temperature/pressure table at right
is for reference only. A unit's temperature/pres-
sure correlation may differ from those listed due
to: variations in evaporator thermistor location,
set-points, where the sealed system is in the
refrigeration cycle, etc.
If a unit is experiencing temperature problems,
it is recommended that you follow the "Pointers"
in the first column of the General
Troubleshooting Guide. After all mechanical
and electrical components have been ruled out,
sealed system pressures can be checked by
applying solder-on process valves and referenc-
ing the preceding page. Do NOT use bolt-on
process valves as they are prone to leak.
This table should only be used as a last quick
check before entering the sealed system.