Page 92
Component Access/Removal
Integrated (
Integrated (
700-
700-
2) Series
2) Series
7-25
#
3756780
- Revision D - July, 2005
700-2 BASE UNIT EXTERIOR COSMETIC
AND MECHANICAL COMPONENTS
Kickplate/Grille Removal (All Base Units)
The kickplate/grille is attached by four screws passing
through the kickplate into adjustable kickplate brackets.
NOTE:
Because drawer panels may extend down in
front of the kickplate/grille, it may be necessary to
remove the bottom drawer to gain access.
To remove the kickplate/grille, extract the four screws
(two on each side) and pull the kickplate grille forward.
Drawer Assembly Removal (All Base Units)
There are inverted channels on both sides of the draw-
er tubs which rest on telescoping drawer slide assem-
blies. A pin at the front of each drawer slide fits into a
hole in the inverted channel of each drawer tub, holding
the drawer assembly in place.
The top drawer assembly has a control cable that must
be disconnected during drawer removal. To remove the
top drawer, pull the drawer open six inches to ten inch-
es, then lift the front of the drawer up and off of the pins
at the end of the drawer slides, then push the slides
back in.
assembly face down directly in front of the unit.
Disconnect the control cable at the interior left rear of
the unit by turning the the collar on the connector coun-
terclockwise and unplugging the pins from the socket.
To remove the bottom drawer assembly, pull the drawer
open and lift the front of the drawer up and off of the
pins at the end of the drawer slides. Pull the drawer
assembly forward and out. Then, push the telescoping
drawer slide assemblies back in.
Figure 7-62. Kickplate/Grille Removal
Kickplate/Grille
Figure 7-63. Drawer Assembly Removal
Hole in Channel
Pin
Drawer Slide
Drawer Assembly
Figure 7-64. Disconnecting Control Cable
Turn collar
counterclockwise
to disconnect