Page 132
Troubleshooting Guides
Integrated (
Integrated (
700-
700-
2) Series
2) Series
8-26
#
3756780
- Revision D - July, 2005
PROBLEM
POSSIBLE CAUSE
TEST / ACTION
EE.
Warm or Normal
Refrigerator Temp’s in Both
Drawers of BR-2 with "EE"
Displayed and “SERVICE”
Flashing
FF.
Warm or Normal Temp’s in
BF/I-2 or BR-2 with “E0” or
“E3” Displayed
GG.
Warm Temp in Lower
Drawer Only of BR-2 without
“SERVICE” Flashing on the
LCD
OR
Inability to Achieve Different
Temperatures Between the
Two Drawers of BR-2
HH.
Product Temperature 10°
or More Colder than
Displayed Temperature
II. 1. “Extremely” Cold
Temperatures Displayed
(1° to 7° in BR-2)
(-21° to -15° in BF/I-2)
2. If outside U.S. -
“Extremely” Warm
Temperatures Displayed
(34° to 45° in BR-2)
(-5° to 5° in BF/I-2)
JJ.
No Ice in BFI-2, "ICE" not
Displayed on LCD
Refrigerator Compartment Thermistor
Disconnected or Shorted
Control Cable Disconnected or Faulty
Disconnected or Faulty Wiring between
Back Duct and Electronic Control Board
Faulty Control Panel or Electronic
Control Board
Baffle Control Fault
a. Baffle Control Stuck Closed
b. Baffle Control Disconnected or
Defective
c. No Signal from Control Board to Baffle
Control
Compartment Thermistor Misread
1. Control Set to Display Celsius but
Customer Thought it Was Fahrenheit
2. If Outside US - Control Set to Display
Fahrenheit but Customer Thought it
Was Celsius
Icemaker System Not Energized
Check refrigerator compartment thermistor
electrical connections from thermistor to P1
on control board. Reconnect / repair con-
nections. Check resistance of refrigerator
compartment thermistor for 30,000 to 33,000
ohms at 32°F. Replace if defective.
Check control cable and connections
between control panel and Methode connec-
tor on back duct. Reconnect, repair or
replace if defective.
Check wiring from Methode connector on
back duct to electronic control board.
Reconnect, repair or replace if defective.
If unit passes all tests above, replace control
panel and electronic control board.
a. Manually open and close baffle control. If
movement is not smooth, replace baffle con-
trol.
b. Check electrical connections from baffle
control to P4 on control board. Reconnect /
repair bad connections.
c. If baffle moves freely and all wiring connec-
tions are good, allow compartment to warm,
then adjust set-point for both compartments
to 34°F. With compressor running, observe
baffle control, if it does not open within three
minutes, replace control board.
Check resistance of compartment thermistor
for 30,000 to 33,000 ohms at 32°F. Replace
if defective.
1. Control set to display Celsius but customer
thought it was Fahrenheit. Switch unit OFF,
then ON, then press & hold Bell key and
UNIT ON/OFF key for 10 seconds.
2. If Outside US - Control set to display
Fahrenheit but customer thought it was
Celsius. Switch unit OFF, then ON, then
press & hold Bell key and UNIT ON/OFF
key for 10 seconds.
Press ICE key. “ ICE” should appear on LCD.
Low Voltage Circuit.
Do NOT apply 115V AC.