Page 142
Technical Data
Integrated (
Integrated (
700-
700-
2) Series
2) Series
9-2
#
3756780
- Revision D - July, 2005
Model 700TC/I-2
REFRIGERATOR
FREEZER
CHARGE
(R-134a Refrigerant)
NOTE:
Always check serial tag for exact charge
NORMAL OPERATING PRESSURES
Low Side
High Side
COMPRESSOR
NOTE:
Always check current parts price list for
possible substitutions.
Service Part No.
Manufacturer
Mfg. Model No.
Original Compressor/Service Compressor Amps
Original Compressor/Service Compressor BTU/H
DEFROST METHOD
DEFROST TERMINATOR
Cut-In Temp.
Cut-Out Temp.
DEFROST HEATER
Watts
Amps
Resistance/Ohms
DRAIN TROUGH HEATER
Watts
Amps
Resistance/Ohms
FILL TUBE HEATER
Watts
Amps
Resistance/Ohms
WATER VALVE
Watts
Amps
Resistance/Ohms (Inductive)
THERMISTORS
(Evap & Compartment)
Resistance/Ohms at 32°F / 0°C
5.5 oz.
5 psi to 30 psi
90 psi to 110 psi
4201880
Embraco
EMI30HER
1.2 / 1.2
280 / 280
“Off Cycle Defrost”
Evap > 38°F before
Compressor ON.
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
-------
30000 - 33000
9 oz.
4” vacuum to 5 psi
90 psi to 120 psi
4201860
Embraco
FGS70 A
1.2 / 1.2
715 / 715
“Adaptive Defrost”
Defrost intervals and
duration vary by unit use.
5 minute compressor
delay after each defrost.
30°F / -1°C
70°F / 21°C
400
3.48
30 - 38
80
0.70
155 - 175
5.1
.044
2300 - 2900
50
0.42
160
30000 - 33000