Global 400mp User Manual
62 of 72
v4.0
Chapter 7: EtherNet/IPTM
17 August 2016
This chapter describes the assembly object connection points provided by the Global 400mp.
Implementation was done against EtherNet/IP
TM
specification edition 1.16 (April 2014) and the
associated CIP specification edition 3.16 (April 2014). As per the EtherNet/IP
TM
specification
for the Assembly Object, instance number and connection point are equivalent. This document
will refer to them as connection point throughout.
Each connection point contains the same fields duplicated for each interface. The first set of
fields corresponds to interface 1, the next set to interface 2, and so on.
Output (O->T) Connection Points
The following connection points are used by the Global 400mp to take input data from the
network. These connection points allow you to control the running operation of the Global
400mp. Other setting parameters may be configured through the vendor-specific objects.
561
Name
Data Type
Description
ARRAY of
STRUCT of:
Parameter selection for each of the 4 interfaces. Each array entry
corresponds to an interface.
Item Number
USINT
Instance number of item to run on the interface. Deactivate any running
parameter or job if 0.
Item Type
USINT
Type of item to run on the interface:
0 - Parameter
2 – Job
Ignored if Item Number is 0.
Batch Reset
USINT
When this value changes, the batch count of the currently running
parameter on the interface is reset.
Suspend
BOOL
When set, suspends on the interface without stopping a running
parameter or job.
Total size: 16 bytes
563
Name
Data Type
Description
ARRAY of
STRUCT of:
Parameter selection for each of the 4 interfaces. Each array entry
corresponds to an interface.
Item Number
USINT
Instance number of item to run on the interface. Deactivate any running
parameter or job if 0.
Item Type
USINT
Type of item to run on the interface:
0 - Parameter
2 – Job
Ignored if Item Number is 0.
Batch Reset
USINT
When this value changes, the batch count of the currently running
parameter on the interface is reset.
Suspend
BOOL
When set, suspends on the interface without stopping a running
parameter or job.
Batch
USINT
Sets the batch size for the selected parameter. If Item Type is not 0
(Parameter), this value is ignored. If this value is 0, the parameter size
stored in the Global 400mp will be used.
Total size: 20 bytes
Содержание Global 400mp
Страница 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Страница 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Страница 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Страница 12: ...Global 400mp User Manual 12 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 2 Using the unit ...
Страница 44: ...Global 400mp User Manual 44 of 72 v4 0 Chapter 4 17 August 2016 Chapter 4 Serial communications ...
Страница 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Страница 61: ...Global 400mp User Manual 61 of 72 v4 0 Chapter 7 EtherNet IPTM 17 August 2016 Chapter 7 EtherNet IPTM ...
Страница 66: ...Global 400mp User Manual 66 of 72 v4 0 Chapter 8 Data Management 17 August 2016 Chapter 8 Data Management ...
Страница 69: ...Global 400mp User Manual 69 of 72 v4 0 Chapter 9 Firmware Updates 17 August 2016 Chapter 9 Firmware Updates ...
Страница 73: ...TEMPLATE GLOBAL 400 ...