This setting controls how long the on-screen indication of a rejected tightening will be shown.
When set to 0, the indication will remain until another tightening is received or the Global
400mp changes or stops the currently running operation. Partial seconds may be entered for this
setting.
Rejects are indicated by shading the screen red behind the parameter that received the reject.
Batch timeout
Default: 1
Range: 0 to 10 seconds
This setting controls how long the on-screen indication of a rejected tightening will be shown.
When set to 0, the indication will remain until another tightening is received or the Global
400mp changes or stops the currently running operation. Partial seconds may be entered for this
setting.
Batch completions are indicated by shading the screen blue or yellow behind the parameter that
received the result to complete a batch.
Cycle timeout
Default: 1
Range: 0 to 10 seconds
This setting controls how long the on-screen indication of an accepted tightening that was not the
last in a batch will be shown. When set to 0, the indication will remain until another tightening
is received or the Global 400mp changes or stops the currently running operation. Partial seconds
may be entered for this setting.
Cycles are indicated by shading the screen green behind the parameter that received the cycle.
Time
This row allows you to set the current time used by the unit. The display order of this field is:
year-month-day hour:minute:second
Each piece of the time may be edited by using the left and right arrows to select the various
pieces of the time and the number keys to set the new value.
Page 2
Serial baud rate
Default: 9600
Values: 9600, 19200, 38400, 57600, 115200
This setting should be set to match the baud rate used by a serial barcode reader or printer, if
either is used. If this setting is not configured correctly, barcodes will not be correctly processed.
Require VIN to run
Default: no
Содержание Global 400mp
Страница 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Страница 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Страница 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Страница 12: ...Global 400mp User Manual 12 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 2 Using the unit ...
Страница 44: ...Global 400mp User Manual 44 of 72 v4 0 Chapter 4 17 August 2016 Chapter 4 Serial communications ...
Страница 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Страница 61: ...Global 400mp User Manual 61 of 72 v4 0 Chapter 7 EtherNet IPTM 17 August 2016 Chapter 7 EtherNet IPTM ...
Страница 66: ...Global 400mp User Manual 66 of 72 v4 0 Chapter 8 Data Management 17 August 2016 Chapter 8 Data Management ...
Страница 69: ...Global 400mp User Manual 69 of 72 v4 0 Chapter 9 Firmware Updates 17 August 2016 Chapter 9 Firmware Updates ...
Страница 73: ...TEMPLATE GLOBAL 400 ...