Global 400mp User Manual
59 of 72
v4.0
Chapter 6: ToolsNet
17 August 2016
Result timeout
Default: 5 seconds
Range: 0 to 60 seconds
This setting controls how long the Global 400mp will wait for a response from the ToolsNet
server when sending a tightening or keep alive packet. If no response is received within the
specified result timeout, the Global 400mp will try again, up to the specified number of retries.
If no response is received after all retries, the ToolsNet connection is considered broken and will
have to be re-established.
Result retries
Default: 2
Range: 0 to 10
This setting controls how many times the Global 400mp will resend a tightening or keep alive
packet to the ToolsNet server before considering the connection broken. If no response is
received within the specified result timeout, the Global 400mp will try again, up to the specified
number of retries. If no response is received after all retries, the ToolsNet connection is
considered broken and will have to be re-established.
Keep alive
Default: 30 seconds
Range: 0 to 3600 seconds
This setting controls how often the Global 400mp will send a keep alive packet to the ToolsNet
server if no other packets are being sent. When set to 0, the Global 400mp does not send keep
alive packets.
This value is recommended to be less than half the inactivity timeout of the server to ensure the
connection is not closed due to a single missed keep alive packet. For example, if the server is
configured to timeout after 30 seconds of inactivity, the keep alive setting on the unit should be
less than 15 seconds.
System number
Default: 1
Range: 0 to 9999
This setting controls the system number the Global 400mp reports to the ToolsNet server in
identification and tightening packets.
The same System number will be used for connections from all interfaces.
Station number
Default: 1
Range: 0 to 9999
Содержание Global 400mp
Страница 1: ...Global 400mp User Manual v4 0 17 August 2016 ...
Страница 4: ...Global 400mp User Manual 4 of 72 v4 0 Quick Start 17 August 2016 Quick Start ...
Страница 9: ...Global 400mp User Manual 9 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 1 Overview ...
Страница 12: ...Global 400mp User Manual 12 of 72 v4 0 Chapter 1 Overview 17 August 2016 Chapter 2 Using the unit ...
Страница 44: ...Global 400mp User Manual 44 of 72 v4 0 Chapter 4 17 August 2016 Chapter 4 Serial communications ...
Страница 57: ...Global 400mp User Manual 57 of 72 v4 0 Chapter 6 ToolsNet 17 August 2016 Chapter 6 ToolsNet ...
Страница 61: ...Global 400mp User Manual 61 of 72 v4 0 Chapter 7 EtherNet IPTM 17 August 2016 Chapter 7 EtherNet IPTM ...
Страница 66: ...Global 400mp User Manual 66 of 72 v4 0 Chapter 8 Data Management 17 August 2016 Chapter 8 Data Management ...
Страница 69: ...Global 400mp User Manual 69 of 72 v4 0 Chapter 9 Firmware Updates 17 August 2016 Chapter 9 Firmware Updates ...
Страница 73: ...TEMPLATE GLOBAL 400 ...