SCALE CONTROL PANEL
CAUTION
•
To avoid damage to the scale electronic components, do not lean on the accessory bracket housing the scale module.
•
Do not use a two or three stage fixed IV pole at the foot end of a stretcher equipped with the scale.
A
Weigh/On
Activates the scale. A weighing is performed when this button is pressed and released.
A weight will be displayed on the display four to ten seconds later. However, no weight
is displayed if the Error -Ex.x or the movement
icon appears on display. The
error will have to be corrected or the stretcher stabilized before using the scale again
(see the Error Code List in the Maintenance Manual).
NOTE
The scale does not work in continuous mode. It must be activated using the Weigh/
On key each time a reading of the patient’s weight is required.
B
Memory
Stores the result of the weighing or recalls on display the weight stored.
C
Zero
Zeroes the weight displayed on screen and the weight stored.
D
lb / kg
Changes the unit of measurement (lb or kg).
E
Change Equipment
To remove or add equipment from the stretcher without removing the patient.
F
Scale Display
The scale will auto shut off after an inactivity period of 30 seconds, except during the
Change Equipment operation where three minutes are allowed. Press the Weigh/On
button to reactivate the scale.
If the patient weighs more than 100 lb (54 kg), the “Error - E05” message will appear
on the display to indicate that the scale should not be used in these conditions, as its
maximal weighing capacity is exceeded.
Some other error messages may be displayed while operating the scale. Refer to the
Error Code List in the Maintenance Manual to understand their signification and what
action to take when they appear.
SCALE OPERATION
CAUTION
The scale weighing zone is made up of all the upper part of the stretcher, including the safety end/siderails, the accessory
brackets, the drainage bag hooks, the chart and monitor holders (optional) located under the mattress support. Ensure
no external object is in contact with the stretcher during a weighing or when zeroing the scale.
NOTE
•
The
icon may appear at any time when using the scale. It indicates that the scale is unable to take a reading of the
patient’s weight because the stretcher is unstable. Simply stabilize the stretcher and repeat the current operation.
•
The
Memory, Change Equipment and Zero
keys may be used to stop the weight reading process when the operation currently
used does not need a weight reading to be displayed.
Scale
Operation
The scale system allows the reading of a patient’s weight in pounds (lb) or kilograms (kg) within ± 0.5 lb (0.2 kg) at 50
lb (22 kg) or less and within ± 1.0 lb (0.4 kg) at ≥ 50 lb (22 kg) when flat. The reading can be stored in memory. The
system also allows to add or remove a device or accessory from the stretcher without removing the patient.