Fuse
LITTELFUSE 0496060.ZXD-UL
Standards
ANSI/AAMI ES60601-1:2012, CAN/CSA-C22.2 No.
60601-1:14, KKK-A-1822F, IEC 60601-1-12:2014
For standards that require specific options, see
Standards with required options
Stryker reserves the right to change specifications without notice.
The yellow and black color scheme is a proprietary trademark of Stryker Corporation.
Hereby, Stryker declares that the radio equipment type short range device is in compliance with Directive 2014/53/EU. The
full text of the EU declaration of conformity is available at the following internet address: http://techweb.med.strykercorp.
com/EMS/EU%20Declaration%20of%20Conformity/index.html.
Labels may be unreadable from a viewing distance greater than 12 inches.
W
WA
AR
RN
NIIN
NG
G
•
Do not operate P
Po
ow
we
err--L
LO
OA
AD
D with a voltage that is inconsistent with the rating on the product.
•
Do not operate P
Po
ow
we
err--L
LO
OA
AD
D above its duty cycle to avoid the risk of equipment damage or smoke hazard.
•
Do not connect P
Po
ow
we
err--L
LO
OA
AD
D to a 24 VDC vehicle circuit. Always connect P
Po
ow
we
err--L
LO
OA
AD
D to a 12.8 VDC-15.6 VDC
vehicle circuit that is on a 15A fuse/breaker to prevent power hazards.
•
P
Po
ow
we
err--L
LO
OA
AD
D operates at 13.56 MHz when you use P
Po
ow
we
err--L
LO
OA
AD
D controls with a powered cot (P
Po
ow
we
err--P
PR
RO
O XT or
P
Po
ow
we
err--P
PR
RO
O IT) that could interfere with other equipment that operate at this frequency band.
•
The use of accessories, transducers, and cables, other than those specified, with the exception of transducers and
cables that are sold by Stryker as replacement parts for internal components, may result in increased emissions or
decreased immunity of the P
Po
ow
we
err--L
LO
OA
AD
D system.
•
Do not use the P
Po
ow
we
err--L
LO
OA
AD
D system and the P
Po
ow
we
err--P
PR
RO
O cot adjacent to or stacked with other equipment. If adjacent
or stacked use is necessary, observe the P
Po
ow
we
err--L
LO
OA
AD
D system to confirm normal operation in the configuration where it
will be used.
•
P
Po
ow
we
err--L
LO
OA
AD
D operates primarily at these frequencies: 70 - 85 kHz for inductive charging and 13.56 MHz±7 kHz,
Amplitude Modulated (OOK), ERP: -82.37 dBm. The inductive charging can operate between these frequencies: 70 -
125 kHz. Other equipment may interfere with the P
Po
ow
we
err--L
LO
OA
AD
D system, even if that other equipment complies with
CISPR emission requirements.
E
En
nvviirro
on
nm
me
en
ntta
all cco
on
nd
diittiio
on
nss
O
Op
pe
erra
attiio
on
n
S
Stto
orra
ag
ge
e a
an
nd
d ttrra
an
nssp
po
orrtta
attiio
on
n
Temperature
130 °F
(54 °C)
-30 °F
(-34 °C)
158 °F
(70 °C)
-30 °F
(-34 °C)
Relative humidity
93%
0%
93%
0%
Atmospheric pressure
1060
hPa
700
1060
hPa
700
C
CA
AU
UT
TIIO
ON
N
•
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at their expense. In the event of interference, please relocate or
reorient the P
Po
ow
we
err--L
LO
OA
AD
D system or interfering product.
•
Always relocate or reorient the P
Po
ow
we
err-- L
LO
OA
AD
D system or interfering product in the event of interference. This device
complies with Part 18 of the FCC Rules.
EN
8
6390-309-002 Rev AB.0
Содержание 6390
Страница 2: ......
Страница 6: ......
Страница 77: ...A An nc ch ho or r a as ss se em mb blly y 6390 001 011 Rev AC Reference only 6390 309 002 Rev AB 0 71 EN ...
Страница 85: ...6390 309 002 Rev AB 0 79 EN ...
Страница 91: ...6390 309 002 Rev AB 0 85 EN ...
Страница 95: ...Torque item B to 68 92 in lb Torque item K to 20 28 ft lb 6390 309 002 Rev AB 0 89 EN ...
Страница 96: ...Torque item DE to 480 600 in lb EN 90 6390 309 002 Rev AB 0 ...
Страница 97: ...Torque item C to 45 max in oz 6390 309 002 Rev AB 0 91 EN ...
Страница 98: ...EN 92 6390 309 002 Rev AB 0 ...
Страница 99: ...6390 309 002 Rev AB 0 93 EN ...
Страница 100: ...EN 94 6390 309 002 Rev AB 0 ...
Страница 101: ...6390 309 002 Rev AB 0 95 EN ...
Страница 102: ...EN 96 6390 309 002 Rev AB 0 ...
Страница 103: ...6390 309 002 Rev AB 0 97 EN ...
Страница 137: ......
Страница 138: ...Stryker Medical 3800 E Centre Avenue Portage MI 49002 USA 6390 309 002 Rev AB 0 WCR AE 5 2021 02 ...