5. Carefully and slowly pinch oil fill plug to release trapped air.
6. Turn release valve counterclockwise to the open position one full turn and lower ram to the lowest
position.
7. Turn release valve (R7) clockwise to the closed position and check for proper pump action. It may be
necessary to perform the above step more than once to assume air is evacuated totally.
8. Secure the handle in place inside the handle socket. Without any weight on the jack. Cycle the lift up
and down several times to insure the hydraulic system is operating properly. (Perform to the Air