![Stratasys Dimension Elite Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/stratasys/dimension-elite/dimension-elite_user-manual_1383536045.webp)
41
As Needed Maintenance
The following maintenance items have no routine schedule but should be tended to as needed.
Chamber Lamp Replacement
Replace the chamber lamp when it burns out.
To replace the chamber lamp:
1.
Power down the system.
2.
Pull the lamp straight out of the socket.
3.
Find the socket wires leading away from the socket.
4.
Pull on the socket wires while inserting the two prongs of the new lamp into the two holes of the
socket. When the lamp is seated into the socket, release the socket wires.
Tip Shroud Replacement
Due to repeated contact with the tip-wipe brush, it is normal for the tip shroud to become worn.
When chronic build up of material around the tip area or clumps of burnt material become
imbedded in the part, replace the tip shroud.
1.
From the display panel, press
Maintenance...
2.
Press
Machine...
3.
Press
Table...
The head temperature decreases.
4.
Using a 1
⁄
8
”
Allen wrench, back out the two head-plate mounting screws approximately 1
⁄
8
”
,
see
Figure 28.
Do not remove the screws.
Note:
There are two chamber lamps in the modeling chamber. They are
located on the front wall of the chamber. One to the upper right, the other to
the upper left.
CAUTION:
Do not touch the new bulb with bare fingers. The natural oil of your skin
can cause premature bulb failure. Grasp the base of the bulb instead.
Use only 24 V, 20 W bulbs.
Note:
Pulling on the socket wires releases the spring-loaded contacts in the
socket. If the lamp is installed without pulling on the socket wires, the lamp
might not be held securely in the socket.
Gloves:
Head area is very hot! Use gloves when installing a new shroud.