2.4.2 Servac Vacuum Regulator
The Servac regulator is cleaned from dust and dirt around the valve cone every 6th
month.
Cleaning can be made without dismounting the regulator. With vacuum on the system
the valve cone is washed with a small brush with soap water, or 1-3 liter of water is
sucked through the valve.
Note! Never let the filter element in the top get wet, as it will be damaged.
The upper filter element is to be exchanged every year.
The main and steering membrane is to be exchanged every 2nd year.
2.4.3 System Vacuum
Type of System
Milk Line
Height to Milk Pipe
Vacuum Level
Pipeline milking system
38 - 40 mm
max. 2 m
48 - 50 kPa
Pipeline milking system
50 - 51 mm
max. 2 m
46 - 48 kPa
Milking parlour
50 - 51 mm
approx. 0,1 m
42 - 44 kPa
Milking parlour
50 - 51 mm
approx. 1m
44 - 46 kPa
Bucket milking system
-
approx. 0,5 m
44 - 46 kPa
2.5 VACUUM
METER
The vacuum meter is always to show the set and prescribed level.
Before each milking it must be checked that the vacuum meter shows the correct level.