Thank you for choosing a
British built appliance by Stoves
We hope the following information
will help you to quickly familiarise
yourself with the features of the
appliance, and to use it successfully
and safely.
Our policy is one of constant
development and improvement. Strict
accuracy of illustrations and specifications
is not guaranteed. Modification to
design and materials may be necessary
subsequent to publication.
This appliance must be installed in
accordance with the regulations in
force, and only in a well ventilated
space. Read the instructions before
installing or using this appliance.
This appliance is designed to be
installed free-standing or flush to base
units.
Your 1st Year Guarantee
To fulfil the conditions of your guarantee,
this appliance must be correctly
installed and operated, in accordance
with these instructions, and only be
used for normal domestic purposes.
Please note that the guarantee, and
Service availability, only apply to the
UK and Republic of Ireland.
Before using the appliance
for
the first time, remove any protective
polythene film and wash the oven
shelves and furniture in hot soapy
water, to remove their protective
coating of oil. Even so, when you first
turn on the oven or grill you may
notice a smell and some smoke.
The
User’s Section
in this handbook
covers the operation of the appliance,
but to help you make the most of your
cooker, we have produced the
accompanying
Cooking Guide
which
gives more details of its features and
benefits.
The
Gas Consumer Council (GCC)
is
an independent organisation which
protects the interests of gas users. If
you need advice, you will find the
telephone number is your local
telephone directory under Gas.
2
INTRODUCTION
Data badge
Located on the lower part of the front
frame.
Type of gas
This cooker must only be used with either
Natural Gas only or LP Gas only, as specified
on the appliance data badge.
Gas category
Natural Gas -
I
2H
, LP Gas -
I
3+
Pressure setting
G20 Natural gas @ 20 mbar
G30 Butane @ 28 - 30 mbar
G31 Propane @ 37 mbar
Aeration
Fixed
Appliance class
Class 1, freestanding
Electrical supply
230 - 240V ~ 50Hz
Warning:
This cooker must be earthed.
Spark generators
Mains powered 6 outlet, controlled by a
single switch at the right of the fascia to
individual electrodes.
Hob
Burners have burner heads and caps
which are removable for cleaning.
Concealed electrodes to each burner.
Electrical ratings
Fan oven element
2400W
Top element
960W
Base element
2 x 835W
Grill
1725 / 2685W
Stir fan
30W
Lights
50W
Cooling fan
23W
Maximum load
2760W
Countries of destination
(GB) Great Britain, (IE) Ireland
31
Hotplate burner
Nominal
Injector
Grammes per hour
Rate Qn
marking
Butane
Propane
Natural
Auxiliary burner
1.0kW
72 X
-
-
Gas
Semi rapid burner (x2)
2.0kW
100 Z
-
-
Rapid burner
2.9kW
1.1 Y
-
-
Wok burner
3.3kW
1.24 Y
-
-
Total Heat Input
∑
Qn 10.2kW
-
-
-
LP Gas
Auxiliary burner
1.0kW
50
73 g/h
72 g/h
Semi rapid burner (x2)
2.0kW
70
145 g/h 143 g/h
Rapid burner
2.9kW
85
211 g/h 207 g/h
Wok burner
3.3kW
90
240 g/h 236 g/h
Total Heat Input
∑
Qn 10.2kW
-
814 g/h 801 g/h
TECHNICAL DATA