30
Conversion instructions
Natural Gas (
I
2H
) G20 @ 20mbar to
LPG (
I
3+
) G30 @ 28mbar / G31 @ 37mbar)
1. To convert hotplate burners
a. Remove pan supports.
b. Remove burner caps & burner heads.
c. Unscrew existing injectors from
hotplate burner bowls.
d. Replace with injectors in conversion
kit as detailed above.
2. To convert hotplate bypass pins
Before carrying out this procedure ensure
that the appliance is disconnected from
gas and electrical supplies.
a. Remove pan supports.
b. Remove burner caps and heads.
c. Remove the control knobs and
timer buttons from the fascia panel.
d. Unscrew and remove the fascia
panel fixing screws located
beneath the fascia panel and gently
lower the fascia panel. Remove
the ignition and light switch leads
from the back of the switches.
e. The hotplate bypass pins are now
accessible through the inner fascia
panel. Unscrew each pin and
replace as detailed above.
3. Data labels
After completing the above procedure
affix label (A), supplied with the
conversion kit and remove the
label currently fitted, label (B).
label (A): PER / FOR G30/G31
label (B): PER / FOR G20.
INSTALLATION INSTRUCTIONS
Moving the cooker
Do not attempt to move the cooker by
pulling on the doors or handles. Open
the door and grasp the frame of the
cooker, taking care that the door does
not shut on your fingers.
Take care to avoid damage to soft or
uneven floor coverings when moving
the appliance. Some cushioned vinyl
floor coverings may not be designed
to withstand sliding appliances without
marking or damage.
Stability bracket
If the cooker is to be fitted with a
flexible inlet connection, a stability
bracket should also be fitted to engage
in the back of the cooker. Make sure
this is re-engaged whenever you move
the cooker for cleaning.
Ventilation
The use of a gas cooking appliance
results in the production of heat and
moisture in the room in which it is
installed. Ensure that the kitchen is
well ventilated: keep natural ventilation
holes open or install a mechanical
ventilation device (mechanical extractor
hood). Prolonged intensive use of the
appliance may call for additional
ventilation, for example, opening of a
window, or more effective ventilation,
for example increasing the level of
mechanical ventilation where present.
Gas & Electrical connection
Please refer to installation instructions
for the Gas & Electrical Safety Regulations
and the Ventilation Requirements.
In your own interest, and that of safety,
it is the law that all gas appliances be
installed by competent persons. Corgi
registered installers undertake to work
to satisfactory standards.
Disconnection of gas and electric
appliances should always be carried
out by competent persons.
Warning:
This appliance must be
earthed.
Glass door panels
To meet the relevant Standards of
Domestic cooking appliances, all the
glass panels on this appliance are
toughened to meet the fragmentation
requirements of BS3193. This ensures
that, in the unlikely event that a panel
breaks, it does so into small fragments
to minimise the risk of injury.
Please take care when handling, using
or cleaning all glass panels as any
damage to the surfaces or edges may
result in the glass breaking without
warning or apparent cause at a later
date. Should any glass panel be
damaged, Stoves strongly recommend
that it is replaced immediately.
3
INTRODUCTION
Содержание 900DFa