Chapter 2. Installation

Order Number:  EK–SMCPC–UG. A01

2–7

able for the ac distribution unit. Since these power cords are country specific, ensure that
your power cord matches those listed in Table 2–2 for your installation.

In general, the power cords listed in Table 2–2 have the following characteristics:

Rated at 10 amps at the specified operating voltage

2.5 meters (8.2 feet) in length

Have a country-specific plug

Have an IEC 320 C-14 compatible connector

The only exception is the BN27S-03 power cord used in Japan and the United States; it
is rated at 15 amps and is 3 meters (9.84 feet) long.

Table 2–2  Country-Specific Power Cords

Country

Voltage

Plug

Length meters (ft.)

Part No,

Australia

250 Vac

AS 3112 - 1981

2.5 (8.2)

BN19H-2E

Central Europe

250 Vac

CEE 7/7 (Schuko)

2.5 (8.2)

BN19C-2E

Denmark

250 Vac

Afsnit

2.5 (8.2)

BN19K-2E

India

250 Vac

BS 546

2.5 (8.2)

BN19S-2E

Ireland

250 Vac

BS 1363

2.5 (8.2)

BN19A-2E

Israel

250 Vac

SI 32

2.5 (8.2)

BN18L-2E

Italy

250 Vac

CEI 213-16/VII

2.5 (8.2)

BN19M-2E

Japan

125 Vac

NEMA 5-15

3.0 (9.8)

BN27S-03

1

New Zealand

250 Vac

AS 3112 - 1981

2.5 (8.2)

BN19H-2E

South Africa

250 Vac

BS 546

2.5 (8.2)

BN19S-2E

Switzerland

250 Vac

SEV 1011

2.5 (8.2)

BN19E-2E

United Kingdom

250 Vac

BS 1363

2.5 (8.2)

BN19A-2E

United States

125 Vac

NEMA 5-15

3 (9.8)

BN27S-03

1

This power cord is rated at 15 amps.

To connect the power cord to the pedestal refer to Figure 2–5 and proceed as follows:

1. Open the door on the front bezel and ensure the power switch on the ac distribution

unit is set to off.

2. Remove the rear bezel as described in Section 4.5.1.

3. Route the female end of the power cord under the handle of the pedestal base and

connect the cord to the ac receptacle on the ac distribution unit.

4. Replace the rear bezel as described in Section 4.5.2.

5. Close the door on the rear bezel and connect the other end of the power cord to an ac

outlet.

6. If installing SBBs, proceed to Section 2.4.3. If the pedestal is preconfigured with

SBBs, proceed to the power-on test in Section 2.5.

Содержание SWXSE-22

Страница 1: ...Wide Expansion Storage Pedestal User s Guide Order Number EK SMCPC UG A01 Digital Equipment Corporation Maynard Massachusetts...

Страница 2: ...e user a license under any patents pending patents trademarks or copyrights or other rights of Digital Equipment Corporation or of any third party FCC Notice This equipment generates uses and may emit...

Страница 3: ...Connectors 2 3 2 3 3 SCSI P Cable Communications 2 3 2 4 Connecting the Pedestal to the Host System 2 3 2 4 1 SCSI P Cable Connections 2 3 2 4 1 1 Routing SCSI Cable under Rear Bezel 2 4 2 4 1 2 Routi...

Страница 4: ...ity Module Status Indicators 4 11 Chapter 5 Illustrated Parts Appendix A StorageWorks Product Specifications A 1 Input Power Requirements A 1 A 2 Power Units A 1 A 3 Physical Specifications A 1 A 4 En...

Страница 5: ...0 4 8 Installing Front Rear Bezel 4 10 4 9 Personality Module Blower Status LEDs 4 11 5 1 Pedestal Field Replaceable Parts 5 1 Tables 2 1 SCSI P Cables 2 2 2 2 Country Specific Power Cords 2 7 3 1 SCS...

Страница 6: ...e changes to affected pages are marked in the guide The following revision history lists all revisions of this publication and their effective dates The publication part number is included in the Revi...

Страница 7: ...e installation procedures Otherwise contact your service representative for installation assistance If you are unfamiliar with the components of the base subsystem it is recommended that you review Se...

Страница 8: ...bezel and a blower There is also a brief troubleshooting tip Chapter 5 Illustrated Parts Illustrated Parts shows an exploded view of the pedestal with a related table which lists the part numbers of...

Страница 9: ...roduct line consists of a vertical free standing modular storage cabinet with an integral SCSI bus backplane that can be configured for either one or two SCSI buses The optional modular components ava...

Страница 10: ...1 3 Pedestal Component Description The components of the pedestal include the following StorageWorks Building Blocks Disk tape CD ROM and optical devices Industry standard 3 5 and 5 25 inch form fact...

Страница 11: ...CSI address is set automatically to the pedestal s slot number 1 3 2 Blower Unit The StorageWorks Wide Expansion Storage Pedestal contains two dual speed blowers for cooling purposes The blowers are m...

Страница 12: ...not used and the personality module automatically terminates the SCSI bus NOTE Connecting JB1 to an open ended SCSI cable will not disable the auto terminator In a two bus configuration with one pede...

Страница 13: ...h or 5 25 inch SBBs The slot numbers and the default SCSI device addresses are the same for slots 0 through 6 Slot 7 is reserved for the power supply and does not have a device address There are two 6...

Страница 14: ...e host system Power on test 2 2 Unpacking Before unpacking the storage pedestal or its components check all packing slips to en sure the correct equipment has been shipped Also inspect the shipping co...

Страница 15: ...d Section 2 3 3 provide more definition Cable length varies with application and must be specified when ordering Figure 2 1 Host to Pedestal SCSI P Cable Table 2 1 SCSI P Cables Cable Host Connector P...

Страница 16: ...nnector on the personality module and the SCSI connector on the host system and then powering on and verifying the status of SBB LED indicators to ensure the equipment is operating properly The inform...

Страница 17: ...and through opening at top of pedestal to front of unit 3 Press tab on right of personality module inward then withdraw module from pedes tal 4 Loop cable down below divider plate and mate right angle...

Страница 18: ...both bezels from pedestal as described in Section 4 5 1 2 Route one end of right angle connector on SCSI P cable through opening above divider plate to front of pedestal 3 Unplug personality module f...

Страница 19: ...Connection Figure 2 5 The pedestal is equipped with an ac distribution unit that provides switch controlled ac power The ac distribution unit is equipped with three short power plugs two at the front...

Страница 20: ...BN19A 2E Israel 250 Vac SI 32 2 5 8 2 BN18L 2E Italy 250 Vac CEI 213 16 VII 2 5 8 2 BN19M 2E Japan 125 Vac NEMA 5 15 3 0 9 8 BN27S 031 New Zealand 250 Vac AS 3112 1981 2 5 8 2 BN19H 2E South Africa 2...

Страница 21: ...r panels to install the de vice To install an SBB complete the following procedure CAUTION Ensure the SCSI ID address of the device being installed does not conflict with any other devices on the bus...

Страница 22: ...ce 4 Set the power switch on the ac distribution unit to on and observe the LEDs on the device to ensure the unit is operating properly Refer to power on test in Section 2 5 below 5 After verifying th...

Страница 23: ...er on test if necessary 1 Verify that the ac power switch on the ac distribution unit bottom module in the pedestal is in the off position 2 Verify that the ac input power and the SCSI cable connectio...

Страница 24: ...Chapter 2 Installation Order Number EK SMCPC UG A01 2 11 Figure 2 8 Storage SBB LEDs...

Страница 25: ...CSI bus It may be reconfigured for two SCSI buses if desired Section 3 5 2 The following rules apply Eight and 16 bit devices can be mixed in the first pedestal when it s configured for either one or...

Страница 26: ...edestal slot numbers and the ID addresses are the same for 3 5 inch hard drive devices none of which have address switches All seven address switches on the personality module are set off down as ship...

Страница 27: ...slots 0 6 Power supplies are available with wattage ratings of 131 145 and 150 Maximum seven drive configurations of 7200 rpm hard disk drives require the use of a 150 watt power supply 3 4 StorageWor...

Страница 28: ...o SCSI buses requires an optional terminator board See Section 3 5 2 below for details The host adapter terminates the other end of the SCSI bus The maximum number of storage devices in a pedestal is...

Страница 29: ...source 3 Remove both bezels from pedestal as described in Section 4 5 1 4 Remove blowers as described in Section 4 4 NOTE An alternative to the following step is to discharge static buildup by momenta...

Страница 30: ...ector on SCSI P cable for devices in slots 1 3 5 and 6 to JB1 on the personality module 11 Connect other end of SCSI P cable to host Refer to Section 2 4 1 for cable routing information 12 Replace blo...

Страница 31: ...Chapter 3 Pedestal Configuration Rules Order Number EK SMCPC UG A01 3 7 Figure 3 5 Pedestal to Host Connections for Two SCSI Buses...

Страница 32: ...itors both blower operation and power The blowers on the rear of the pedestal provide cooling and the pedestal power supply provides 5 Vdc and 12 Vdc to operate the storage devices The personality mod...

Страница 33: ...Power supply bad Replace faulty supply NOTE When the pedestal is equipped with two power supplies you must observe the LEDs on both power supplies Table 4 2 to determine the status Table 4 2 Pedestal...

Страница 34: ...EDs BBU Charge LED BBU Status LED Indication On Off Normal status BBU is fully charged and operational Off On Normal status BBU is charging Off Flashing Error status Power supply failure BBU in use Of...

Страница 35: ...xpansion Storage Pedestal 4 4 Order Number EK SMCPC UG A01 CAUTION Removing an SBB when the left LED is on or flashing can cause the loss or corruption of data Figure 4 3 3 5 inch SBB LEDs Figure 4 4...

Страница 36: ...storage device perform the following procedure CAUTION Ensure the replacement SBB is the same type as the one being replaced Also always use both hands when handling a device and be careful not to tou...

Страница 37: ...dc power supply is controlled by a switch on the ac distribution unit Setting this switch to off removes power from all power supplies in the pedestal To remove power from a single power supply simpl...

Страница 38: ...imilar to replacing a drive as shown in Figure 4 5 3 Insert the replacement redundant supply into the guide slots and push it in until the tabs lock into place 4 Reconnect the input power cable to the...

Страница 39: ...the removal of a blower To replace a blower perform the following procedure 1 Determine which of the two blowers has failed by feeling the air flow at the bottom of each blower 2 Remove the rear bezel...

Страница 40: ...interchangeable 4 5 1 Remove Front Rear Bezel To remove a front or rear bezel refer to Figure 4 7 and proceed as follows 1 Open front door of bezel 2 Unlock bezel with key supplied then store key in...

Страница 41: ...o install a bezel at the front or rear of the pedestal refer to Figure 4 8 and proceed as follows 1 With bezel door open engage tabs at base of bezel under pedestal 2 Push top of bezel forward until i...

Страница 42: ...system error log to pinpoint device errors Also unplug the faulty device and try reseating the unit to ensure a proper connection with the pedestal backplane slot connector 4 7 Personality Module Sta...

Страница 43: ...atus Indication Lower blower Upper blowerr On Off Lower blower has failed Upper blower to high speed Lower blower Upper blowerr Off On Upper blower has failed Lower blower to high speed Lower blower U...

Страница 44: ...ins an illustrated breakdown of the field replaceable parts in the StorageWorks Wide Expansion Storage Pedestal The information consists of an exploded view of the pedestal and its associated part num...

Страница 45: ...niversal AC power supply 2 SWXBP SC Battery Backup Unit BBU 3 SWxx5 xx 5 25 inch disk drive 4 SWxx3 xx 3 5 inch disk drive 5 BA35X PA 3 5 inch filler panel 6 70 29761 03 Fan carrier blower assy two sp...

Страница 46: ...ure does not disable the storage devices In most cases battery backup units BBUs can be combined with the pedestal power unit to provide extended system data integrity See the following table for more...

Страница 47: ...c Autoranging feature Yes Yes No Yes Output voltages 12 Vdc 5 Vdc 12 Vdc 5 Vdc 12 Vdc 5 Vdc 12 Vdc 5 Vdc Output power 131 W 145 W 200 W peak power for 16 32 or 64 s 150 W Sequential device spin up at...

Страница 48: ...le count 0 5 micron or larger not to exceed 500 000 particles per cubic ft of air Inlet air volume 0 026 cubic m per second 50 cubic ft per minute Maximum Operating Environment Range Temperature 10 to...

Страница 49: ...device Stabilize the device and the SBB in the operating environment for 6 hours or until the condensation is no longer visible whichever is longer Do not insert the storage device into the pedestal...

Страница 50: ...may void the user s authority to operate the equipment Operation of this equipment in a residential area may cause interference in which case the user at his own expense will be required to take what...

Страница 51: ...Deskside Expansion Enclosure at the side of the desk SWXSE 22 SBB Pedestal 5 7 5 7 40 40 SWXSE 22 SBB Pedestal with Seven Disk Drives 5 8 5 8 40 40 Sound Pressure Level Sound Power Level LpAm dBA LW A...

Страница 52: ...41 41 Deskside Expansion Enclosure neben einem Schreibtisch SWXSE 22 SBB Pedestal 5 7 5 7 40 40 SWXSE 22 SBB Pedestal mit 7 Disk Drives 5 8 5 8 41 41 Schalldruckpegel Schalleistungspegel LpAm dBA LW A...

Страница 53: ...igen und an das rtliche Fernmeldeamt zu schicken Der obere Teil bleibt beim Ger t Betreiberhinweis Das Ger t wurde funktechnisch sorgf ltig entst rt und gepr ft Die Kennzeichnung mit der Zulassungsnum...

Страница 54: ...d is used when conditions preclude the use of a hot swap method Normally this method is only used when installing or upgrading a StorageWorks subsystem disk A storage device supporting random access t...

Страница 55: ...MB s and 16 bit SCSI 2 for synchronous transfer of data at rates equal to or exceeding 20 MB s Small Computer System Interface See SCSI storage array An integrated set of storage devices supported dev...

Страница 56: ...3 3 drive 5 25 inch 1 1 2 8 3 4 E electrical shock risks 4 8 error conditions 4 1 2 3 5 11 F front rear bezel removal see bezel removal G guide 1 2 I input SCSI connector 1 4 5 2 4 5 6 installation o...

Страница 57: ...4 5 reshipment 2 1 routing SCSI cable 2 4 5 6 S SCSI 1 1 cables and connectors 2 1 2 3 connector securing mechanisms 2 2 device addresses 1 5 3 2 SCSI P cable 2 1 2 3 cable connections 2 3 SCSI bus 2...

Страница 58: ...acy correct presentation of facts Completeness adequate information Clarity easy to understand Organization logical sequence of information Layout easy to follow subject matter Indexing easy to locate...

Отзывы: