Chapter 2. Installation
Order Number: EK–SMCPC–UG. A01
2–5
Figure 2–3 Routing SCSI Cable under Rear Bezel
2.4.1.2 Routing the SCSI Cable through Removable Tab (Figure 2–4)
NOTE
The following procedure routes the SCSI "P" cable through
the removable filler tab at the right rear of the pedestal. If an
alternate path is desired, remove the appropriate tab and
route the cable to its destination as directly as possible.
1. Remove both bezels from pedestal as described in Section 4.5.1.
2. Route one end of right-angle connector on SCSI "P" cable through opening above
divider plate to front of pedestal.
3. Unplug personality module from pedestal and withdraw it.
4. Loop cable down below divider plate and mate right-angle connector with SCSI con-
nector JA1 on personality module (side connector when viewed from front).
5. Replace personality module in pedestal, ensuring that connector at rear of personality
module fully engages backplane connector in pedestal.
6. Take either bezel and slide out filler tab at lower left corner (as viewed from inside
bezel).