Chapter IV : S9 III Operations
32
Keep pressing I + F keys and wait for all lights flashing at the same time, then press F key to
choose the working mode: press I key when ROVER is lighted to choose the working mode of
rover. Wait for several seconds and then press the F key down for about 5 seconds, after one
beep release F key, press F key to choose the data link. When RADIO is lighted, press I key to
confirm the choosing of built-in radio data link mode. When GSM/GPRS is lighted, press I key to
confirm the choosing of GSM/GPRS data link mode. When
EXTERNAL
is
lighted, press I key to
confirm the chosen external radio data link mode.
Base mode
Keep pressing I + F keys and wait for six lights flashing at the same time, then press F key to
choose the working mode: press I key when BASE is lighted to choose the working mode of
base.
The setting of the data link is the same described in the Rover mode configuration.
Static mode
Keep pressing I + F keys and wait for six lights flashing at the same time, then press F key to
choose the working mode, press I key when the STATIC is lighted to choose the static mode.
The next time you open the receiver, the working mode will be the last selected.
If you prefer, you can select the correct data link by handheld software, but remember that you
can’t switch from one working mode to another by handheld, but only by hand or by STONEX
®
Assistant (see Cap. V).
By handheld software or by Assistant you can set some rover parameters, for instance
sampling interval, minimum elevation angle, antenna height, etc. Without modifying the
parameters the receiver will work with default parameters.
The static mode parameters cannot be selected by the controller, but only by Assistant.