Owner’s Manual #513625
9
SU412 Model Machines
L.
Press the Clean button to stop the auger rotating.
Turn the pump off.
M.
Optional: Fill the bucket in the cab with about
2 gallons of detergent solution (Palmolive or
equivalent). Turn the pump on and follow steps
I through L above.
NOTE
Running the detergent solution through the machine
will make cleaning parts easier after disassembly.
N.
Remove the bucket from the cab and turn on the
pump to clear the remaining liquid in the hoses.
Open the spigot to empty the freezing cylinder.
O.
Turn the Main Freezer Power switch and pump
switch off.
3.4 DISASSEMBLY OF MACHINE PARTS
WARNING
Moving machinery can grab, mangle and dismem-
ber. Place the Main Freezer Power Off/On switch in
the OFF position before disassembling for cleaning
or servicing.
Before using the machine for the fi rst time, complete
machine disassembly, cleaning and sanitizing proce-
dures need to be followed. Routine cleaning intervals
and procedures must comply with the local and state
health codes. Inspection for worn or broken parts should
be made at every disassembly of the machine. All worn
or broken parts should be replaced to ensure safety to
both the operator and the customer and to maintain good
machine performance and a quality product.
To disassemble the machine, refer to the following steps:
A. REMOVE
BLENDER
1.
Unplug the blender.
2.
Remove the blender agitator and splash shield
if it is installed.
a. Hold the blender shaft and turn the agitator
counterclockwise.
b. Loosen knobs holding the blender splash shield
assembly in place and remove the assembly
3.
Remove the knobs on the front door. Remove
the blender assembly and set aside.
NOTE
Support the blender with one hand while removing
the knobs on the door to prevent the blender from
dropping.
3.3 EMPTYING THE FREEZING CYLINDER
If the machine is empty, go to Section 3.4
A.
Unplug the blender.
B.
Remove the blender agitator and splash shield.
1. Hold the blender shaft and turn the agitator
counterclockwise.
2. Loosen knobs holding the blender splash shield
assembly in place and remove the assembly
(Fig. 3-3).
C
Make sure the Main Freezer Power switch and
the pump switch are on.
D.
Press the Clean button.
E.
In the cab, remove the mix pickup assembly from
the mix container by pulling the retaining clip
from the container cover. Place the mix pickup
assembly in an empty bucket.
F.
Remove the mix container and container covers.
NOTE
The mix container must be cleaned on a regular
basis. Refer to State and local codes for frequency
of cleaning.
G.
When the product in the freezing cylinder has
melted (after about 5 minutes), open the spigot
to drain.
H.
Fill the bucket in the cab with cool tap water.
I.
Press the air bleed valve on the front door to
release pressure in the cylinder. Repeat 2-3 times
at 30 second intervals until water has fi lled the
freezing cylinder.
J.
Press the Clean button and let the augers rotate
for at least 30 seconds.
K.
Open the spigots to drain the water. If it is not
clear, allow the cylinder to refi ll with water and
drain it again.
Figure 3-3 Removing Splash Shield Bracket