![Stoelting SU412 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/stoelting/su412/su412_operators-manual_1381570011.webp)
Owner’s Manual #513625
5
SU412 Model Machines
Figure 2-3 Mix Pump Connections for Standard Mix Container
2.
Connect the free end of the tubing to the mix check
valve. Observe the direction of the check valve
fl ow arrow. Secure with a hose clamp. Connect a
24” (61cm) length of 3/8” (9,5mm) ID plastic food
grade tubing to the free end of the check valve
and secure with a hose clamp.
3. Connect
the
elbow
fi tting to the free end of the
tubing. Connect the opposite end of the elbow
to 1/4” ID tan tubing on the left side of the pump
head. Secure with hose clamps (Fig. 2-3).
When Using Bag Connection System (BCS) with Three
Bags (optional kit):
The position of the three bags in the mix container is im-
portant. The bag that is connected nearest the outlet of
the manifold drains last and should be placed at the back
of the mix container. The mix low level indicator relies on
proper bag placement.
1.
Connect 3/8” (9,5mm) ID plastic food grade tubing
to a bag adapter. Secure with hose clamps.
2.
Slide the hose clip over free end of 3/8” (9,5mm)
ID plastic food grade tubing. Attach the free end
of the tubing to a manifold adapter. Secure with
a large hose clamp or equivalent.
3.
Push the manifold adapter with spring and valve
into the left port (nearest the manifold outlet) of
the mix inlet manifold and secure with a retaining
clip. (Fig. 2-5).
Figure 2-4 BCS Mix Inlet Manifold
Mix Outlet
Drains
Last